PHOENIX CONTACT 3025042
PHOENIX CONTACTNon disponibile

PT 6-DREHSI (5X20) - Fuse modular terminal block

Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 1000 V, nominal current: 10 A, connection method: Push-in connection, Rated cross section: 6 mm2, cross section:0.5 mm2- 10 mm2, mounting type: NS 35/7,5, NS35/15, color: black
Cod. Articolo: 3025042
Cod. Fornitore: 3025042
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
NotesGeneral
Note: The current is determined by the fuse used, the voltage by the fuse or selected light indicator.
Product propertiesProduct type: Fuse terminal block
Number of connections: 2
Number of rows: 1
Potentials: 1
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Electrical propertiesFuse type: Glass / ceramics / ...
Rated surge voltage: 6 kV
Maximum power dissipation for nominal condition: 1.31 W
Fuse: G / 5 x 20
Maximum power dissipation: max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)
Connection dataNumber of connections per level: 2
Nominal cross section: 6 mm²
Rated cross section AWG: 10
Stripping length: 10 mm ... 12 mm
Internal cylindrical gage: A5
Connection in acc. with standard: IEC 60947-7-3
Conductor cross section rigid: 0.5 mm² ... 10 mm²
Cross section AWG: 20 ... 8 (converted acc. to IEC)
Conductor cross section flexible: 0.5 mm² ... 10 mm²
Conductor cross section, flexible [AWG]: 20 ... 8 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve): 0.5 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve): 0.5 mm² ... 6 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 0.5 mm² ... 2.5 mm² When using TWIN ferrules, we recommend a minimum ferrule length of 13mm.
Nominal current: 10 A
Maximum load current: 10 A (the current is determined by the fuse used)
Nominal voltage: 1000 V
Connection cross sections directly pluggable
Conductor cross section rigid: 1 mm² ... 10 mm²
Conductor cross-section flexible (ferrule without plastic sleeve): 1 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve): 1 mm² ... 6 mm²
DimensionsWidth: 12.3 mm
End cover width: 2.2 mm
Height: 77.7 mm
Depth: 49.8 mm
Depth on NS35/7,5: 51.3 mm
Depth on NS35/15: 58.8 mm
Material specificationsColor: black
Flammability rating according to UL 94: V0
Insulating material group: I
Insulating material: PA
Static insulating material application in cold: -60°C
Relative insulation material temperature index (Elec., UL 746 B): 130°C
Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162): passed
Specific optical density of smoke NFPA 130 (ASTM E 662): passed
Smoke gas toxicity NFPA 130 (SMP 800C): passed
Mechanical propertiesMechanical data
Open side panel: No
Environmental and real-life conditionsOscillation/broadband noise
Specification: DINEN50155 (VDE0115-200):2018-05
Spectrum: Service life test category2, bogie-mounted
Frequency: f1 = 5 Hz to f2 = 250 Hz
ASD level: 6.12 (m/s²)²/Hz
Acceleration: 3.12g
Test duration per axis: 5 h
Test directions: X-, Y- and Z-axis
Result: Test passed
Shocks
Specification: DINEN50155 (VDE0115-200):2018-05
Pulse shape: Half-sine
Acceleration: 30g
Shock duration: 18ms
Number of shocks per direction: 3
Test directions: X-, Y- and Z-axis (pos. and neg.)
Result: Test passed
Ambient conditions
Ambient temperature (operation): -60°C ... 105°C (max. short-term operating temperature RTI Elec.)
Ambient temperature (storage/transport): -25°C ... 60°C (for a short time, not exceeding 24h, -60°C to +70°C)
Ambient temperature (assembly): -5°C ... 70°C
Ambient temperature (actuation): -5°C ... 70°C
Permissible humidity (storage/transport): 30 % ... 70 %
Standards and regulationsConnection in acc. with standard: IEC 60947-7-3
MountingMounting type: NS 35/7,5
NS35/15
Specifiche
ECLASSECLASS-11.0: 27141116
ECLASS-12.0: 27141116
ECLASS-13.0: 27250113
ETIMETIM 9.0: EC000899
UNSPSCUNSPSC 21.0: 39121400
Descrizione
Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Push-in connection, cross section: 0.5 mm²- 10 mm², AWG: 20 - 8, nominal current: 10 A, nom. voltage: 1000 V, width: 12.3 mm, fuse type: G / 5 x 20, mounting type: NS 35/7,5, NS 35/15, color: black
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00581.pdf

Approvals_00877.pdf

Manufacturer_declaration_02739.pdf

Manufacturer_declaration_04937.pdf

Manufacturer_declaration_17133.pdf

Safety_notes_00001.pdf

Technical_drawing_42213.pdf