Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 3058127
PHOENIX CONTACTNon disponibile

RSC 4 - Bolt connection terminal block

Feed-through terminal block with bolt connection method, cross section: 0.1 - 6 mm2, AWG: 26 - 10, width 9 mm, color: gray
Cod. Articolo: 3058127
Cod. Fornitore: 3058127
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
NotesGeneral
Note: The rated insulation voltage applies to insulated cable lugs acc. DIN 46237:1970-07 and for uninsulated cable lugs acc. DIN 46234:1980-03 with shrink sleeve.
Product propertiesProduct type: Bolt connection terminal block
Pitch: 9 mm
Number of connections: 2
Number of rows: 1
Potentials: 1
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Electrical propertiesRated surge voltage: 8 kV
Maximum power dissipation for nominal condition: 1.02 W
Connection dataNumber of connections per level: 2
Nominal cross section: 4 mm²
Stripping length: The stripping length depends on the specification provided by the cable lug manufacturer.
Connection in acc. with standard: IEC 60947-7-1
Nominal current: 32 A
Maximum load current: 32 A
Nominal voltage: 800 V
Cable lug connection DIN46234:1980-03
Connection in acc. with standard: DIN46234:1980-03
DIN46237:1970-07
Cross section: 0.1 mm² ... 6 mm²
0.5 mm² ... 2.5 mm²
Cross section range AWG: 26 ... 10 (converted acc. to IEC)
Hole diameter: 4.3 mm
Width: 8 mm
Bolt diameter: 4 mm
Screw thread: M4
Tightening torque: 1.2 ... 1.4 Nm
Identification color of ring cable lugs : red: 1 mm²
Identification color of ring cable lugs : blue: 2.5 mm²
DimensionsWidth: 9 mm
End cover width: 2.2 mm
Height: 53.3 mm
Depth on NS32: 52.1 mm
Depth on NS35/7,5: 47.1 mm
Depth on NS35/15: 54.6 mm
Pitch: 9 mm
Material specificationsColor: gray
Flammability rating according to UL 94: V0
Insulating material group: I
Insulating material: PA
Static insulating material application in cold: -60°C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): 130°C
Relative insulation material temperature index (Elec., UL 746 B): 130°C
Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354): 28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162): passed
Specific optical density of smoke NFPA 130 (ASTM E 662): passed
Smoke gas toxicity NFPA 130 (SMP 800C): passed
Electrical testsSurge voltage test
Test voltage setpoint: 9.8 kV
Result: Test passed
Temperature-rise test
Requirement temperature-rise test: Increase in temperature ≤45K
Result: Test passed
Short-time withstand current 4 mm²: 0.48 kA
Short-time withstand current 6 mm²: 0.72 kA
Power-frequency withstand voltage
Test voltage setpoint: 2 kV
Result: Test passed
Mechanical propertiesMechanical data
Open side panel: Yes
Mechanical testsMechanical strength
Result: Test passed
Attachment on the carrier
DIN rail/fixing support: NS32/NS35
Test force setpoint: 1 N
Result: Test passed
Environmental and real-life conditionsNeedle-flame test
Time of exposure: 30 s
Result: Test passed
Oscillation/broadband noise
Specification: DINEN50155 (VDE0115-200):2008-03
Spectrum: Service life test category1, classB, body mounted
Frequency: f1 = 5 Hz to f2 = 150 Hz
ASD level: 0.2g²/Hz
Acceleration: 0.8g
Test duration per axis: 5 h
Test directions: X-, Y- and Z-axis
Result: Test passed
Shocks
Specification: DINEN50155 (VDE0115-200):2008-03
Pulse shape: Half-sine
Acceleration: 5g
Shock duration: 30ms
Number of shocks per direction: 3
Test directions: X-, Y- and Z-axis (pos. and neg.)
Result: Test passed
Ambient conditions
Ambient temperature (storage/transport): -25°C ... 60°C (for a short time, not exceeding 24h, -60°C to +70°C)
Ambient temperature (assembly): -5°C ... 70°C
Ambient temperature (actuation): -5°C ... 70°C
Permissible humidity (storage/transport): 30 % ... 70 %
Standards and regulationsConnection in acc. with standard: IEC 60947-7-1
MountingMounting type: NS 35/7,5
NS35/15
Specifiche
ECLASSECLASS-11.0: 27141120
ECLASS-13.0: 27250101
ETIMETIM 9.0: EC000897
UNSPSCUNSPSC 21.0: 39121400
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00001.pdf

Approvals_00007.pdf

Approvals_00207.pdf

Approvals_00208.pdf

Manufacturer_declaration_05416.pdf

Safety_notes_00001.pdf

Technical_drawing_43548.pdf