Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PROSOFT TECHNOLOGY PLX82-EIP-61850
PROSOFT TECHNOLOGYNon disponibile

EtherNet/IP™ Server to IEC 61850 Client Gateway

Cod. Articolo: PLX82-EIP-61850
Cod. Fornitore: PLX82-EIP-61850
PROSOFT TECHNOLOGY


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Caratteristiche Tecniche
Features and Benefits
The supplied configuration software enables you to import all of your relevant IED tags into your Logix controller tag database reducing configuration time and errors
Multiple EtherNet/IP™ I/O connections give you large amounts of data to transfer in a real time environment
Standards-based identification of device types simplifies implementation and maintenance
SNTP/NTP Client
The gateway supports a Simple Network Time Protocol (SNTP/NTP) client service that can synchronize the gateway’s time by periodic update requests to a Coordinated Universal Time (UTC) system. The user can configure the SNTP/NTP server details in ProSoft 61850 Configuration Manager. The resolution of the time is in milliseconds (ms).
EtherNet/IP Server
The gateway supports multiple communication methods to fit your application. In addition, it features multiple EtherNet/IP™ I/O Connections. (20 maximum, providing support for 10,000 bytes of input data and 9920 bytes of output data)
Configuration
Configuration is accomplished through the dedicated PLX82-EIP-61850 Configuration Manager software which can be downloaded from our website, www.prosoft-technology.com. The configuration utility automatically creates the Add-On Instruction to be used in RSLogix™ 5000/Studio 5000 and brings the data over as configured.
Specifiche
ACSI Basic Conformance
SCSMs supported:SCSM: IEC 61850 8.1(MMS) used
ACSI Model Conformance
Reporting:Buffered Report Control Block (BRCB)
Reporting:Unbuffered Report Control Block (URCB)
GOOSE:Direct-with-Normal-Security
GOOSE:SBO-with-Normal-Security
GOOSE:Direct-with-Enhanced-Security
GOOSE:SBO-with-Enhanced-Security
Logical Nodes:IEC 61850 Logical Nodes, including Logical Nodes for Hydro Power Plants and Logical Nodes for Wind Power Plants
Configurable Parameters:MMS Command Delay
Status Data:Status available per node
Status Data:Report and GOOSE status available
Status Data:High-level status data available from Ethernet/IP
Status Data:Client through the Ethernet/IP Server (for example PLC or PAC)
SNTP/NTP Client
Configurable Parameters:SNTP/NTP server synchronization rate in minutes
Configurable Parameters:SNTP/NTP server address
EtherNet/IP Server
Class 1 Messaging:I/O connections for real-time data transfer
Class 3 Messaging:PLC messaging support
Hardware
Power Supply:24 VDC nominal
Power Supply:10 to 36 VDC power input allowed
Power Supply:Positive, Negative, GND Terminals
Power Supply:2.5 mm screwdriver blade
Current Load:200 mA max @ 24 VDC
Current Load:150 mA max @ 32 VDC
Current Load:450 mA max @ 10 VDC
Operating Temperature:-25°C to 70°C (-13°F to 158°F)
Storage Temperature:-40°C to 85°C (-40°F to 185°F)
Relative Humidity:5% to 95%, with no condensation
Dimensions (H x W x D):11.99 x 5.1 x 10.62 cm 4.72 x 2.0 x 4.18 in
Shock:IEC 60068-2-27; 15G @ 11ms (Operational)
Shock:IEC 60068-2-27; 30G @ 18ms (Non-Operational)
Vibration:IEC 60068-2-6; 5G, 10 to 150 Hz
LED Indicators:ERR, CFG, FLT, PWR
Ethernet Ports (E1, E2):10/100 Base-T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Ports (E1, E2):Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Shipped with Each Unit:One - Ethernet straight-through cables
Shipped with Each Unit:One - J180 screw terminal plug
Shipped with Each Unit:One - ProSoft Solutions DVD
Shipped with Each Unit:One - HRD250 screwdriver
Descrizione
The ProSoft Technology® EtherNet/IP™ to IEC 61850 communication gateway allows Rockwell Automation® PACs to interface with IEC 61850 Intelligent Electronic Devices (IED) such as substation power monitors and relays. The gateway acts as an IEC 61850 Clientpolling the devices on your network. The two ports allow the IEC 61850 and EtherNet/IP™ protocols to reside on separate subnets.