ROCKWELL AUTOMATION 100-E09KD400
ROCKWELL AUTOMATION 100-E09KD400
ROCKWELL AUTOMATIONNon disponibile

Contactor, IEC, 9 A, 100-250V 50-60 Hz/100-250V DC, 4 NO Poles, 0 NO 0 NC Auxiliary Contacts, Screw Terminals

100-E MCS-E Contactor, 9A, AC3 duty, 100-250V AC 50/60Hz / 100-250V DC Electronic Coil, 4 N.O. 0 N.C. Main Contact Configuration
Cod. Articolo: 100-E09KD400
Cod. Fornitore: 100-E09KD400
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
Number of normally open contacts as main contact4
Number of normally closed contacts as main contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Vibration resistanceIEC 60068-2-6
Shock resistanceIEC 60068-2-27
Altitude, max3000 m of installation site
Switching frequency, max600 ops/hr, AC-1
WeightAC/DC (electronic): 0.43 kg (0.95 lbs.)
Protection classContactor main contact: IP2X
Voltage type for actuatingAC/DC
Rated control supply voltage at AC 50 Hz100 V
Rated control supply voltage at AC 60 Hz100 V
Rated control supply voltage at DC100 V
Type of electrical connection of main circuitScrew connection
Rated impulse voltage withstand (Uimp)6 kV
Operating time, closing delay40 ms
Optional overload relaysElectronic
Main current circuit resistance0.41 mΩ
Rated isolation voltage (Ui)690V per IEC
FunctionNon-reversing contactor
Standard coil, pick-up50VA/50 W @ 24-60V AC, 20-60V DC
Standard coil, hold-in2.2VA/2 W @ 24-60V AC, 20-60V DC
General purpose current (enclosed)13.8 A @ 600V per UL/CSA
Power dissipation0.8 W per pole at Ie, AC-1, 400V
FLA20 A @ 600V, 3-phase per UL/CSA HVAC applications
Rated operational current and power (enclosed)9.5 A @ 125V DC, with 3-poles in series per UL/CSA
LRA80 A @ 550-600V, 3-phase AC per UL/CSA HVAC applications
Electromagnetic compatibilityIEC 60947-1 - Environment A and B (100-E09...E38 only)
Total power dissipation2.3 W at Ie, AC-3, 400V, AC/DC control (120-250V)
Operating limits, dropout(≤0.60) x Us @ DC control
Operating limits, pick-up(0.85...1.1) x Us @ 50/60 Hz
MCCB current ratingType 2 (per IEC 60947-4-1): 28 A @ 400V, 70 kA available fault current
DIN fuses (gG) current ratingType 2 (per IEC 60947-4-1): 6 A @ 690 V, 60 kA available fault current
Rated voltage (Ue)24, 48, 110, 220, 440V DC
Rated operational current and power5.8 A @ 115V AC, 500000 electrical operations, 1-phase per UL/CSA elevator duty
Coil voltage100...250V AC/DC
Switching of lighting loadsTungsten lamps: 20 A @ 600V, 3-phase (break all lines) per UL/CSA
UL class RK5 fuses ratingType 1 Combination (per UL 60947 and CSA 22.2 No. 14): 30 A @ 600V, 5 kA available fault current
Rated operational current (Ie)9.5 A @ 500V, Star-Delta starting (50 Hz)
UL class J and CSA HRCI-J fuses ratingType 1 Combination (per UL 60947 and CSA 22.2 No. 14): 30 A @ 600V, 100 kA available fault current
UL inverse-time circuit breakerType 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60 A @ 600V, 5 kA available fault current
Switching of power transformersApparent power: 8 kVA @ 415V, AC-6a, 50 Hz (n = 30)
Rated operational power (Pe)9 kW @ 240V, AC-1 active power load (50/60 Hz), ambient temperature 70 °C (158 °F)
Switching of DC loads4-poles in series: 6 A @ 440V (Shunt-wound motors-starting, reverse current breaking, reversing, stepping: DC-3 at 60 °C)
Optional accessoriesSide-or front-mount auxiliary contacts, Mechanical interlocks, Connecting bars
FeaturesPanel mounting or mounting on 35 mm DIN rail, AC/DC electronic coil, Made of environmentally friendly materials
Climatic withstandCategory B according to IEC 60947-1, annex Q
Ambient temperatureStorage: -60 °C...80 °C (-76 °F...176 °F)
Coil insulation classClass F per IEC 60947-4-1