Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

ROCKWELL AUTOMATION 100-K12D300
ROCKWELL AUTOMATION 100-K12D300
ROCKWELL AUTOMATIONNon disponibile

Miniature Contactor, 12 A, IEC, 110V 50Hz/120V 60Hz, 3 N.O./ 1 N.C. Poles, No Auxiliary Contact, Screw Type Terminals, Single Pack: Quantity of 1

Miniature Contactor, Screw Type Terminals, 12A, System Control Voltage: 110V 50Hz/120V 60Hz, 3 N.O. / 1 N.C. Main Contacts, 1
Cod. Articolo: 100-K12D300
Cod. Fornitore: 100-K12D300
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
Number of normally open contacts as main contact3
Number of normally closed contacts as main contact1
Vibration resistanceIEC 60068-2
Shock resistanceIEC 60068-2
Altitude, max2000 m (NN) per IEC 60947-4
LifespanMechanical DC control: 15000000 ops
Switching frequency, max250 ops/h, AC-4 (approximately 200000 operations)
Recommended torque10.6 lb.in
WeightDC: 0.2 kg
Conductor cross sectionMain contact, 2 conductor: 1...2.5 mm^2 + 1...4 mm^2
Protection classIP2X
Voltage type for actuatingAC
Rated control supply voltage at AC 50 Hz110 V
Rated control supply voltage at AC 60 Hz120 V
Rated control supply voltage at DC0 V
Type of electrical connection of main circuitScrew connection
Rated impulse withstand voltage (Uimp)6 kV
Optional overload relaysBimetallic
Main current circuit resistance2.2 mOhm
Power dissipation (all circuits)0.9 W @ 400V, AC-3, Ie
Rated filament current9 A @ 230/240V, AC-5b
Rated isolation voltage (Ui)IEC: 690V, UL, CSA: 600V
Switching of motor load11 A @ 400V, AC-7b (50 Hz)
PackagingSingle pack (quantity of 1)
Auxiliary contactsIP2X
Rated current (enclosed)9.6 A @ 230V, 3-phase per UL/CSA
Rated power (enclosed)7.5 Hp @ 575V, 3-phase per UL/CSA
Auxiliary contact configurationNo auxiliary contact
Capacitance, max750 µF @ short-circuit current of 10 kA
General purpose current (enclosed)18 A per UL/CSA
Operating time, closing delay6...12 ms DC (conventional)
Switching of low inductive loads20 A @ 400V, AC-7a per IEC 61095 (50 Hz)
Short time withstand (Icw)96 A for 10 s, 60 °C
Operating time, opening delay8...12 ms with integrated diode
Coil consumption, hold-inCold 3.0 W, warm 2.6 W DC (conventional)
Coil consumption, pick-upCold 3.0 W, warm 2.6 W DC (conventional)
Total power dissipationDC control: 3.5 W @ 400V, AC-3, Ie
Operating limits, dropout(0.2...0.75) x Us @ 50 Hz, 60 Hz, 50/60 Hz
Switching of lampsGas discharge lamps, open: 18 A @ 40 °C, AC-5a
Insulation class of the coilClass F per IEC 60085, Class 105 insulation system per UL 508
Rating for switching AC motors4-poles: 7-1/2 Hp @ 575V (AC-2, AC-3), 3-phase (60 Hz)
Switching of hermetically sealed cooling compressor motors18 A @ 400V, AC-8a (manual reset of overload release (50 Hz))
Operating limits, pick-up(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 Hz
UL class K5 and RK5 fuses rating40 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
DIN fuses (gG, gL) current ratingType 2 (per IEC 60947-4-1): 20 A @ 400 V, 50 kA available fault current
Rated operational current (Ie)9.2 A @ 500V, AC-4 (50 Hz), ambient temperature 60 °C
UL class J and CSA HRCI-J fuses rating30 A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
Switching of power transformersApparent power: 5 kVA @ 500V, AC-6a, 50 Hz (n = 30)
Rated operational power (Pe)8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °C
Switching of DC loads3-poles in series: 9 A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
Optional accessoriesFront-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocks
FeaturesMini-contactors, Uniform panel mounting dimensions, Panel mounting or mounting on 35 mm DIN Rail, Made of environmentally friendly materials
UL class CC and CSA HRCI-MISC fuses rating30 A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
Climatic withstandIEC 60068-2-30
Ambient temperatureStorage: -55...80 (-67...176)