Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

ROCKWELL AUTOMATION 100S-E26KY404C
ROCKWELL AUTOMATIONNon disponibile

IEC 26 A Safety Contactor

100S-E MCS-E Safety Contactor, 26A, AC3 duty, 48-130V AC 50/60Hz / 48-130V DC Electronic Coil, 0 N.O. 0 N.C. Standard & 0 N.O. 4 N.C. Lower Power Auxiliary Contacts
Cod. Articolo: 100S-E26KY404C
Cod. Fornitore: 100S-E26KY404C
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
Number of normally open contacts as main contact4
Number of normally closed contacts as main contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact4
LengthApprox 45 mm
Vibration resistanceIEC 60068-2-6
Shock resistanceIEC 60068-2-27
HeightApprox 86 mm
WidthApprox 101 mm
Altitude, max3000 m of installation site
Switching frequency, max600 ops/hr, AC-1
WeightAC/DC (electronic): 0.48 kg (1.06 lbs.)
Protection classContactor main contact: IP2X
Voltage type for actuatingAC/DC
Rated control supply voltage at AC 50 Hz48 V
Rated control supply voltage at AC 60 Hz48 V
Rated control supply voltage at DC48 V
Type of electrical connection of main circuitScrew connection
Rated impulse voltage withstand (Uimp)6 kV
Operating time, closing delay40 ms
Operating time, opening delay11 ms
Main current circuit resistance0.29 mΩ
Rated isolation voltage (Ui)690V per IEC
FunctionNon-reversing safety contactor
Standard coil, pick-up50VA/50 W @ 48...130V AC/DC
Standard coil, hold-in2.2VA/2 W @ 48...130V AC/DC
General purpose current (enclosed)24 A @ 600V per UL/CSA
Power dissipation2.4 W per pole at Ie, AC-1, 400V
Short time withstand (Icw)3-pole: 700 A for 1 s (40 °C)
FLA45 A @ 600V, 3-phase per UL/CSA HVAC applications
Rated operational current and power (enclosed)7.5 Hp @ 220-240V, 3-phase per UL/CSA
LRA270 A @ 440-480V AC, 3-phase per UL/CSA HVAC applications
Electromagnetic compatibilityIEC 60947-1 - Environment A and B (100-E09...E38 only.)
Total power dissipation4.7 W at Ie, AC-3, 400V, AC/DC control (120-250V)
Operating limits, dropout(≤0.60) x Us @ DC control
Rating for switching AC motors3-poles: 7.5 Hp @ 230V, AC-2, AC-3 (60 Hz)
Operating limits, pick-up(0.85...1.1) x Us @ 50/60 Hz
MCCB current ratingType 2 (per IEC 60947-4-1): 56 A @ 400V, 70 kA available fault current
DIN fuses (gG) current ratingType 2 (per IEC 60947-4-1): 62 A @ 400V, 100 kA available fault current
Rated voltage (Ue)24V, 48V, 110V, 220V, 440V DC
Rated operational current and power9.6 A @ 230V AC, 500000 electrical operations, 1-phase per UL/CSA elevator duty
Switching of lighting loadsTungsten lamps: 45 A @ 600V, 3-phase (break all lines) per UL/CSA
UL class RK5 fuses ratingType 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60 A @ 600V, 5 kA available fault current
Rated operational current (Ie)4-poles: 45 A @ 40 °C, AC-1 (690V)
UL class J and CSA HRCI-J fuses ratingType 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60 A @ 600V, 100 kA available fault current
UL inverse-time circuit breakerType 1 Combination (per UL 60947 and CSA 22.2 No. 14): 100 A @ 600V, 25 kA available fault current
Switching of power transformersApparent power: 9 kVA @ 200V, 60 Hz (n = 30)
Rated operational power (Pe)6.5 kW @ 220-240V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F)
Switching of DC loads4-poles in series: 45 A @ 220V (non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
Optional accessoriesSide-mount auxiliary contacts, Mechanical interlocks
FeaturesMirror contact performance on auxiliary contacts, Red N.C. low-power auxiliary contacts used for feedback circuit, SUVA third-party certification, AC/ DC operating coils, Mirror contact symbol on front
Climatic withstandCategory B according to IEC 60947-1, annex Q
Ambient temperatureStorage: -60...80 °C (-76...176 °F)
Coil insulation classClass F per IEC 60947-4-1