Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

ROCKWELL AUTOMATION 140M-C2N-A63
ROCKWELL AUTOMATION 140M-C2N-A63
ROCKWELL AUTOMATION 140M-C2N-A63
ROCKWELL AUTOMATIONNon disponibile

Motor Circuit Protector Circuit-Breaker

MCP, Standard Magnetic Trip (Fixed at 13 x le), 0.63 A, Std. Performance, Frame Size C
Cod. Articolo: 140M-C2N-A63
Cod. Fornitore: 140M-C2N-A63
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
Number of poles3
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100 kA
Complete device with protection unitYes
Rated permanent current Iu0.63 A
Rated voltage230 V
Type of control elementTurn button
Rated frequency60 Hz
Magnetic release current per IEC8.2 A
Rated operational current (Ie) per IEC0.63 A
Rated supply current (Ie)0.1 A
Ultimate short circuit breaking capacity (Icu) per IEC100 kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC100 kA @ 690V
Magnetic trip current8.2 A
Hp rating, max0.33 Hp @ 575V, 3-phase
Rated insulation voltage (Ui)690V per IEC, SEV, VDE0660
KW rating, max0.25 kW @ 690V (AC-3), 3-phase
Switching of standard motors per IEC0.25 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IECNo back-up fuse required @ 690V
Short circuit current (Type 2 coordination), max65 kA @ 480V
Short circuit current for group motor installation with 100-C contactor, max65 kA @ 480V, UL 508—manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max65 kA @ 480V, UL 508—manual motor controller
Electrical life cycle100000 operations (Ie maximum)
Rated thermal current (Ith)0.1...32 A @ 60 °C ambient temperature
Fuse or circuit breaker per NEC, max450 A, UL 508—manual motor controller with 100-C contactor
Rated impulse withstand voltage (Uimp)Main circuits/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max65 kA @ 480V, UL 508—manual motor controller
Short circuit current for motor disconnect, max65 kA @ 480V, UL 508—manual motor controller
Short circuit current for self-protected combination motor controller with 100-C contactor, max65 kA @ 480Y/277V, UL-508—Type E self-protected combination motor controller
Magnetic release current (±20 %)Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges
Protection typeFixed magnetic only (13 x In)
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Switching frequency, max25 ops/h
Total power loss (Pv) for circuit breaker at rated load operating temperature6 W
Ultimate interrupting current for group motor65 kA @ 480V
Phase loss protectionDifferential release
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Degree of protection (IP)IP2X
Weight315 lb
Mechanical life operations100000 /h
Breaking capacityStandard breaking capacity
Factory optionNo circuit-breaker auxiliary or trip contacts
Vibration resistanceOperation (60068-2-6): 5 G
Shock resistanceTransport (60068-2-27): 30 G, 11 ms, all axes
Ambient storage temperature-40 °C
Ambient operating temperature-25 °C
Ambient temperature compensation-20 °C
Site altitudeto 2000 m N.N. (6561 ft)
Dependence on temperatureNo reduction @ 60 °C (140 °F)
Pollution degree3
Moisture heat (60068-2-3)40 °C, relative humidity 93 %, 56 days
Dry heat (60086-2-2)100 °C, relative humidity < 50 %, 7 days
Moisture change climate (600068-2-30)23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles
Frame sizeFrame size C, 32 A
Contactor size (Type 2 coordination), min100-C09 @ 600V
Contactor size, min100-C09, UL-508—Type E self-protected combination motor controller
Device constructionBuilt-in device fixed built-in technique
Utilization categoryMotor starter: AC-3 (IEC60947-4-1)