With integrated auxiliary switch | No |
With integrated under voltage release | No |
Rated short-circuit breaking capacity lcu at 400 V, AC | 100 kA |
Rated operation power at AC-3, 400 V | 0.09 kW |
Rated permanent current Iu | 0.4 A |
Rated operation power at AC-3, 230 V | 0.06 kW |
Rated operating voltage | 230 A |
Type of control element | Turn button |
Overload release current setting | 0.25 A |
Type of electrical connection of main circuit | Screw connection |
Magnetic release current per IEC | 8.2 A |
Rated operational current (Ie) per IEC | 0.4 A |
Magnetic trip current | 8.2 A |
Rated supply current (Ie) | 0.1 A |
Short circuit current (Icu) for group motor installation, max | 65 kA @ 480V |
Current range | 0.25 to 0.40 A |
Ultimate short circuit breaking capacity (Icu) per IEC | 100 kA @ 690V |
Rated service short circuit breaking capacity (Ics) per IEC | 100 kA @ 690V |
Hp rating, max | 0.25 Hp @ 575V, 3-phase |
Rated insulation voltage (Ui) | 690V per IEC, SEV, VDE0660 |
Electrical life cycle | 100000 operations (Ie maximum) |
Switching of standard motors per IEC | 0.18 kW @ 690V (AC-3), 3-phase |
KW rating, max | 0.18 kW @ 690V (AC-3), 3-phase |
Back up fuse (gG, gL) current rating (if Icc ââ°¥ Icu ) per IEC | No back-up fuse required @ 690V |
Short circuit current (Type 2 coordination), max | 65 kA @ 480V |
Total power loss (Pv) for circuit breaker | 6...11.5 W @ rated load operating temperature |
Rated thermal current (Ith) | 0.1...32 A @ 60 ðC ambient temperature |
Short circuit current for tap conductor protection, max | 65 kA @ 480Y/277V per UL 508-manual motor controller |
Short circuit current for combination motor controller, max | 65 kA @ 480V/277V per UL 508-self-protected (Type E) |
Fuse or circuit breaker per NEC, max | 450 A, UL 508-manual motor controller |
Rated impulse withstand voltage (Uimp) | Main circuits/overvoltage category: 6 kV/III |
Short circuit current for group motor installation, max | 65 kA @ 480V, UL 508-manual motor controller |
Short circuit current for motor disconnect, max | 65 kA @ 480V, UL 508-manual motor controller |
Magnetic release current | Fixed setting 16...21 x Ie max. Ie max. = maximum values of setting ranges (ñ20 %) |
Number of poles | 3 |
With thermal protection | Yes |
Phase failure sensitive | Yes |
Switch off technique | Thermomagnetic |
Switching frequency, max | 25 ops/h |
Trip class | 10 |
Rated frequency | 50/60 Hz |
Phase loss protection | Differential release |
Width | 45 mm |
Depth | 70 mm |
Height | 90 mm |
Frame size | Frame size C, 32 A |
Contactor size (Type 2 coordination), min | 100-C09 @ 600V |
Device construction | Built-in device fixed built-in technique |
Degree of protection (IP) | IP2X |
Weight | 315 lb |
Mechanical life operations | 100000 /h |
Breaking capacity | Standard breaking capacity |
Shock | Transport (60068-2-27): 30 G, 11 ms, all axes |
Protection type | Adjustable thermal/fixed magnetic (fixed at 16...20 x In) |
Factory option | No circuit-breaker auxiliary or trip contacts |
Vibration | Operation (60068-2-6): 5 G |
Ambient storage temperature | -40 ðC |
Ambient operating temperature | -25 ðC |
Site altitude | 2000 m (NN) |
Moisture heat | 40 ðC, relative humidity 93 %, 56 days, (60068-2-3) |
Dry heat | 100 ðC, relative humidity < 50 %, 7 days, (60086-2-2) |
Dependence on temperature | No current reduction @ 60 ðC |
Moisture change climate | 23 ðC/83 % relative humidity and 40 ðC/92 % relative humidity, 56 cycles, (600068-2-30) |
Pollution degree | 3 |
Ambient temperature compensation, max | -20 ðC |
Utilization category | Motor starter: AC-3 (IEC60947-4-1) |
Overload protection characteristics | IEC 60947-4-1 motor protection |