Motor Protection Circuit-Breaker

MPCB, High Magnetic Trip (Fixed at 16...20 x le), 0.4 - 0.63 A, Std. Performance, Frame Size C
Cod. Articolo: 140M-C2T-A63
Cod. Fornitore: 140M-C2T-A63
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Caratteristiche Tecniche
With integrated auxiliary switchNo
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, AC100 kA
Rated operation power at AC-3, 400 V0.18 kW
Rated permanent current Iu0.63 A
Rated operation power at AC-3, 230 V0.09 kW
Rated operating voltage230 A
Type of control elementTurn button
Overload release current setting0.4 A
Type of electrical connection of main circuitScrew connection
Magnetic release current per IEC13 A
Rated operational current (Ie) per IEC0.63 A
Magnetic trip current13 A
Rated supply current (Ie)0.1 A
Short circuit current (Icu) for group motor installation, max65 kA @ 480V
Current range0.40 to 0.63 A
Ultimate short circuit breaking capacity (Icu) per IEC100 kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC100 kA @ 690V
Hp rating, max0.33 Hp @ 575V, 3-phase
Rated insulation voltage (Ui)690V per IEC, SEV, VDE0660
Electrical life cycle100000 operations (Ie maximum)
Switching of standard motors per IEC0.25 kW @ 690V (AC-3), 3-phase
KW rating, max0.25 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IECNo back-up fuse required @ 690V
Short circuit current (Type 2 coordination), max65 kA @ 480V
Total power loss (Pv) for circuit breaker6...11.5 W @ rated load operating temperature
Rated thermal current (Ith)0.1...32 A @ 60 °C ambient temperature
Short circuit current for tap conductor protection, max65 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max65 kA @ 480V/277V per UL 508-self-protected (Type E)
Fuse or circuit breaker per NEC, max450 A, UL 508-manual motor controller
Rated impulse withstand voltage (Uimp)Main circuits/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max65 kA @ 480V, UL 508-manual motor controller
Short circuit current for motor disconnect, max65 kA @ 480V, UL 508-manual motor controller
Magnetic release currentFixed setting 16...21 x Ie max. Ie max. = maximum values of setting ranges (±20 %)
Number of poles3
With thermal protectionYes
Phase failure sensitiveYes
Switch off techniqueThermomagnetic
Switching frequency, max25 ops/h
Trip class10
Rated frequency50/60 Hz
Phase loss protectionDifferential release
Width45 mm
Depth70 mm
Height90 mm
Frame sizeFrame size C, 32 A
Contactor size (Type 2 coordination), min100-C09 @ 600V
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP2X
Weight315 lb
Mechanical life operations100000 /h
Breaking capacityStandard breaking capacity
ShockTransport (60068-2-27): 30 G, 11 ms, all axes
Protection typeAdjustable thermal/fixed magnetic (fixed at 16...20 x In)
Factory optionNo circuit-breaker auxiliary or trip contacts
VibrationOperation (60068-2-6): 5 G
Ambient storage temperature-40 °C
Ambient operating temperature-25 °C
Site altitude2000 m (NN)
Moisture heat40 °C, relative humidity 93 %, 56 days, (60068-2-3)
Dry heat100 °C, relative humidity < 50 %, 7 days, (60086-2-2)
Dependence on temperatureNo current reduction @ 60 °C
Moisture change climate23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles, (600068-2-30)
Pollution degree3
Ambient temperature compensation, max-20 °C
Utilization categoryMotor starter: AC-3 (IEC60947-4-1)
Overload protection characteristicsIEC 60947-4-1 motor protection
Specifiche
Specifications
Trip Range:0.4 - 0.63A
Type:Standard Breaking Capacity
System Voltage Data
Supply Voltage:480V 60Hz
Circuit Breaker
Circuit Breaker Type:Motor Protection Circuit Breaker
Adj. Thermal Current Range (A):0.4 - 0.63A
Application:High Magnetic Trip (Fixed at 16...20 x le)
Frame Size:Frame Size C
Breaking Capacity:Standard Breaking Capacity
UL Listed Application Ratings:UL 508 - Manual Motor Controller
Short Circuit Coordination
Coordination Type:Type 1
Options
Side Mount Shunt Trip and Undervoltage Release:None
Front Mount Auxiliary and Trip Contacts:None
Side Mount Auxiliary and Trip Contacts (TESTDESC):None
Descrizione
Circuit-Breaker, Motor Protection, 0.4 - 0.63A, MxRtg MCPs(no OvPrt)is 1200.0A, Frame Size C, Standard Breaking Capacity, No Bus Bar Mount, 0.63 A, No Knob Adaptor Modification, for Thermal Overloads, None, None, None, Hgh Mgntc Trp(Fxd at 16-20xle), None, None, Trigger Constraints, None, No Options Right