Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

ROCKWELL AUTOMATION 140M-D8N-C32
ROCKWELL AUTOMATION 140M-D8N-C32
ROCKWELL AUTOMATION 140M-D8N-C32
ROCKWELL AUTOMATION 140M-D8N-C32
ROCKWELL AUTOMATION 140M-D8N-C32
ROCKWELL AUTOMATIONNon disponibile

Motor Circuit Protector Circuit-Breaker

MCP, Standard Magnetic Trip (Fixed at 13 x le), 32 A, High Performance, Frame Size D
Cod. Articolo: 140M-D8N-C32
Cod. Fornitore: 140M-D8N-C32
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Number of poles3
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50 kA
Complete device with protection unitYes
Rated permanent current Iu32 A
Rated voltage230 V
Type of control elementTurn button
Magnetic release current per IEC448 A
Rated operational current (Ie) per IEC32 A
Current range32 A
Rated supply current (Ie)1.6 A
Ultimate interrupting current for group motor installation30 kA @ 480V
Ultimate short circuit breaking capacity (Icu) per IEC65 kA @ 230/240V
Rated service short circuit breaking capacity (Ics) per IEC50 kA @ 230/240V
Magnetic trip current448 A
Hp rating, max7.5 Hp @ 200V, 3-phase
Rated insulation voltage (Ui)Rated 690V per IEC, SEV, VDE0660
KW rating, max7.5 kW @ 230V (AC-3), 3-phase
Switching of standard motors per IEC7.5 kW @ 230/240V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IECNo back-up fuse required @ 230/240V
Short circuit current (Type 2 coordination), max65 kA @ 480V
Total power loss (Pv) for circuit breaker6...11.6 W @ rated load operating temperature
Electrical life cycle100000 operations (Ie maximum)
Rated thermal current (Ith)1.6…32 A up to 60 °C ambient temperature
Fuse or circuit breaker per NEC, max450 A, UL 508—manual motor controller
Fuse or circuit breaker rating per NEC, max450 A, UL 508—manual motor controller with 100-C contactor
Rated impulse withstand voltage (Uimp)Main circuits (Uimp)/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max65 kA @ 480V, UL 508—manual motor controller with 100-C contactors
Short circuit current for motor disconnect, max65 kA @ 480V, UL 508—manual motor controller with 100-C contactors
Magnetic release current (±20 %)Fixed setting 13...14 x Ie maximum (Ie maximum = maximum values of setting ranges)
Protection typeFixed magnetic only (13 x In)
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Switching frequency, max25 ops/h
Rated frequency50/60 Hz
Phase loss protectionDifferential release
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Degree of protection (IP)IP2X
Weight365 lb
Mechanical life operations100000 /h
Breaking capacityHigh breaking capacity
VibrationOperation (60068-2-6): 5 G
ShockTransport (60068-2-27): 30 G, 11 ms, all axes
Factory optionNo circuit-breaker auxiliary or trip contacts
Ambient storage temperature-40 °C
Ambient operating temperature-25 °C
Ambient temperature compensation-20 °C
Site altitude2000 m (NN)
Dependence on temperatureNo reduction @ 60 °C (140 °F)
Pollution degree3
Moisture heat (60068-2-3)40 °C, relative humidity 93 %, 56 days
Dry heat (60086-2-2)100 °C, relative humidity < 50 %, 7 days
Moisture change climate (600068-2-30)23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles
Frame sizeFrame size D, 32 A
Contactor size (Type 2 coordination), min100-C37 @ 600V
Contactor size, min100-C37, UL 508—manual motor controller with 100-C Contactors
Device constructionBuilt-in device fixed built-in technique
Utilization categoryMotor starter: AC-3 (IEC60947-4-1)
Specifiche
Specifications
Type:High Breaking Capacity
System Voltage Data
Supply Voltage:480V 60Hz
Circuit Breaker
Circuit Breaker Type:Motor Circuit Protector
Rated Operational Current (A):32A
Application:Standard Magnetic Trip (Fixed at 13 x le)
Frame Size:Frame Size D
Magnetic Trip Current (A):448A Fixed
Breaking Capacity:High Breaking Capacity
UL Listed Application Ratings:UL 508 - Manual Motor Controller
Short Circuit Coordination
Coordination Type:Type 1
Options
Side Mount Shunt Trip and Undervoltage Release:None
Front Mount Auxiliary and Trip Contacts:None
Side Mount Auxiliary and Trip Contacts (TESTDESC):None