Motor Protection Circuit Breaker, A Frame, 0.40-0.63 A, Trip Class 10A, Standard Breaking Capacity, Standard Magnetic Trip (Fixed at 12.5 x le)

140MP Motor Protection Circuit Breaker / Manual Motor Starter, Frame Size A, 5 kA, Adjustable Thermal/Fixed Magnetic MPCB, 0.40 - 0.63A
Cod. Articolo: 140MP-A3E-A63
Cod. Fornitore: 140MP-A3E-A63
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
With integrated under voltage releaseNo
Rated operating voltage0 A
Type of control elementTurn button
Type of electrical connection of main circuitScrew connection
Rated impulse withstand voltage (Uimp)6 kV
Magnetic trip current7.9 A
Short circuit current for group motor, max30 kA @ 480V
Motor current adjustment range0.40...0.63 A
Short circuit current Icu, max100 kA @ 400V
Rated operational current (Ie)0.63 A
Ultimate short circuit breaking capacity (Icu) per IEC100 kA @ 690V AC
Rated service short circuit breaking capacity (Ics) per IEC50 kA @ 400V AC
Insulation voltage (Ui)Rated 690V
Hp rating, max0.33 Hp @ 575V, 3-phase
KW rating, maxAC-3: 0.25 kW @ 690V, 3-phase
Short circuit current ratingType 1 coordination: 5 kA @ 600V AC
Branch circuit protection per NEC/CEC, maxUL 60947 manual motor controller: 175 A
Trip class10 A
Fuse or circuit breaker size per NEC, maxUL 60947-4-1 manual motor controller: 175 A
Short circuit current, maxType 2 coordination, IEC 60947-4-1: 50 kA @ 400V
Fuse or circuit breaker per NEC, maxUL 60947-4-1 manual motor controller: 175 A
Short circuit current for group motor installation, maxUL 60947 manual motor controller: 5 kA @ 600V
Short circuit current for motor disconnect, maxUL 60947 manual motor controller: 5 kA @ 600V
Number of poles3
With thermal protectionYes
Phase failure sensitiveYes
Max current Ie32 A
Maximum operating voltage (UL)600 V
Disconnect function per IEC/EN 60947-2Yes
Rated operating voltage (Ue)690V AC
Rated frequency50/60 Hz
Number of operationsMechanical: 100.000 cycles, Electrical: 100000 cycles (0.1...16 A), 50000 cycles (20...32 A)
Power loss5.1 W @ 0.16...1.6 rated operating current, 5.4 @ 2.5...6.3 rated operating current, 7.2 @ 10...12 rated operating current, 8.4 @ 16...25 rated operating current, 9.3 @ 32 rated operating current
Altitude2000 m
Pollution degree3
Storage ambient air temperature-50 °C
Operating ambient air temperatureOpen compensated: -25...+55 °C, Open: -25...+70 °C, Enclosed: 0...+40 °C
Utilization categoryCircuit breaker: A per IEC60947-2, Motor starter: AC-3 per IEC60947-4-1
Device constructionBuilt-in device fixed built-in technique
MountingDIN Rail (EN 60715)
Group mounting side by sideUp to 40 °C (104 °F)
Resistance to shock25 G/11 ms per IEC 60068-2-27
Resistance to vibration5 G/3 ... 150 Hz per IEC 60068-2-6
Degree of protectionHousing: IP20, Main terminals: IP10