ROCKWELL AUTOMATION 140M-F8E-C45
ROCKWELL AUTOMATION 140M-F8E-C45
ROCKWELL AUTOMATION 140M-F8E-C45
ROCKWELL AUTOMATION 140M-F8E-C45
ROCKWELL AUTOMATIONDisponibile

Motor Protection Circuit-Breaker

MPCB, Standard Magnetic Trip (Fixed at 13 x le), 32 - 45 A, High Performance, Frame Size F
Cod. Articolo: 140M-F8E-C45
Cod. Fornitore: 140M-F8E-C45
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Caratteristiche Tecniche
With integrated auxiliary switchNo
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, AC65 kA
Rated operation power at AC-3, 400 V22 kW
Rated permanent current Iu45 A
Rated operation power at AC-3, 230 V13 kW
Rated operating voltage230 A
Type of control elementTurn button
Overload release current setting32 A
Type of electrical connection of main circuitScrew connection
Magnetic release current per IEC585 A
Magnetic trip current, nom585 A
Rated operational current (Ie) per IEC45 A
Rated supply current (Ie)6.3 A
Short circuit current (Icu) for group motor installation, max65 kA @ 480V
Short circuit current (Type 2 coordination) with 100-C IEC contactor, max65 kA @ 480V
Current range32...45 A
Ultimate short circuit breaking capacity (Icu) per IEC65 kA @ 400/415V AC
Rated service short circuit breaking capacity (Ics) per IEC6 kA @ 690V AC
Insulation voltage (Ui)Rated 690V per IEC
Hp rating, max40 Hp @ 575V, 3-phase
Electrical life cycle30000 operations (Ie maximum)
Short circuit current for self-protected combination motor controller with 100-C contactor, max65 kA @ 480Y/277V, UL 508âۉ€Type E
Switching of standard motors per IEC40 kW @ 690V (AC-3), 3-phase
KW rating, max40 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IECNo back-up fuse required @ 230/240V AC
Short circuit current for combination motor controller with 100-C IEC contactor, max65 kA @ 480Y/277V, UL 60947-4-1âۉ€Type F
Total power loss (Pv) for circuit breaker7…22 W @ rated load/operating temperature
Short circuit current for group motor installation with 100-C IEC contactor, max65 kA @ 480V, UL 60947-4-1âۉ€manual motor controller
Short circuit current for motor disconnect with 100-C IEC contactor, max65 kA @ 480V, UL 60947-4-1âۉ€manual motor controller
Rated thermal current (Ith)6.3...45 A up to 60 °C (140 °F) ambient temperature
Short circuit current for tap conductor protection, max65 kA @ 480Y/277V, UL 60947-4-1âۉ€manual motor controller
Short circuit current for combination motor controller, max65 kA @ 480V/277V, UL 60947-4-1 self-protected (Type E)
Fuse or circuit breaker per NEC, max600 A, UL 60947-4-1âۉ€manual motor controller
Rated impulse withstand voltage (Uimp)Main circuits (Uimp)/overvoltage category: 6 kV/III, 8 kV (disconnect)
Short circuit current for group motor installation, max65 kA @ 480V, UL 60947-4-1âۉ€manual motor controller
Short circuit current for motor disconnect, max65 kA @ 480V, UL 60947-4-1âۉ€manual motor controller
Number of poles3
With thermal protectionYes
Phase failure sensitiveYes
Switch off techniqueThermomagnetic
Switching frequency, max25 ops/h
Trip class10
Rated frequency45 Hz
Phase loss protectionDifferential release
Fuse or circuit breaker rating with 100-C IEC contactor per NEC, max600 A, UL 60947-4-1âۉ€manual motor controller
Width54 mm
Depth110 mm
Height111.4 mm
Contactor size (Type 2 coordination) with 100-C IEC contactor, min100-C37 @ 600V
Frame sizeFrame size F, 45 A
Contactor size, min100-C37, UL-508 âۉ€Type E self-protected combination motor controller
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP2X
Weight782 lb
Mechanical life operations30000 /h
Breaking capacityHigh breaking capacity
ShockTransport (60068-2-27): 30 G/11 ms, OFF
Protection typeAdjustable thermal/fixed magnetic (13 x In)
Factory optionNo circuit-breaker auxiliary or trip contacts
VibrationOperation (60068-2-6): 5 G
Ambient storage temperature-40 °C
Ambient operating temperature-25 °C
Ambient temperature compensation-25 °C
Site altitudeto 2000 m N.N. (6561 ft)
Dependence on temperatureNo reduction @ 60 °C (140 °F)
Magnetic release current (±20 %)Fixed setting: 18…22 x Ie maximum (Ie maximum = maximum values of setting ranges) for T version
Pollution degree3
Climatic resistanceOperating humidity/moisture heat (60068-2-3): 5...95% non-condensing
Utilization categoryMotor starter: AC-3 (IEC60947-4-1)
Overload protection characteristicsIEC 60947-4-1 motor protection
Specifiche
Specifications
Trip Range:32 - 45A
Type:High Breaking Capacity
System Voltage Data
Supply Voltage:480V 60Hz
Circuit Breaker
Circuit Breaker Type:Motor Protection Circuit Breaker
Adj. Thermal Current Range (A):32 - 45A
Application:Standard Magnetic Trip (Fixed at 13 x le)
Frame Size:Frame Size F
Breaking Capacity:High Breaking Capacity
UL Listed Application Ratings:UL 508 - Manual Motor Controller
Short Circuit Coordination
Coordination Type:Type 1
Options
Side Mount Shunt Trip and Undervoltage Release:None
Front Mount Auxiliary and Trip Contacts:None
Side Mount Auxiliary and Trip Contacts (TESTDESC):None
Descrizione
Circuit-Breaker, Motor Protection, 32 - 45A, MxRtg MCPs(no OvPrt)is 1200.0A, Frame Size F, High Breaking Capacity, No Bus Bar Mount, 45 A, No Knob Adaptor Modification, for Thermal Overloads, None, None, Std Mgntc Trp (Fxd at 13 x le), None, None, None, Trigger Constraints, None, No Options Right