Caratteristiche Tecniche
Download
Caratteristiche Tecniche
With displayYes
Voltage type for actuatingAC
Rated operating voltage Ue200 V
Rated control supply voltage at AC 50 Hz110 V
Rated control supply voltage at AC 60 Hz110 V
Overload current for line connected devices416 A
Overload current for delta connected devices533 A
Controller typeSoft starter
Control optionsNone
Trip classes10, 15, 20 and 30
Trip current rating117% of motor FLC
Heatsink fan rating150VA @ 110/120V AC or 220/240V AC
DV/DT protectionRC snubber network for power circuit
Repetitive peak inverse voltage rating1400V per UL/CSA/NEMA for power circuit
Operating frequency50/60 Hz for power circuit
Line connected motor power, max900 kW @ 500V AC, 50 Hz, 3-phase
Delta connected motor power, max900 kW @ 400/415V AC, 50 Hz, 3-phase
Rated impulse voltage6000V per IEC for power circuit
Dielectric withstand2500V per IEC for power circuit
Line connected motor current416...1250 A @ 600/Y/690V AC, 3-phase
Delta connected motor current533...1600 A @ 500/575V AC, 3-phase
Ampere tested european style, maxTwo fuses in parallel 6,6URD33xxx1250 @ 690V for maximum FLC
Ampere tested north american style, maxTwo fuses in parallel A070URD33xxx1250 @ 690V for maximum FLC
Transient protectionMetal oxide varistors: 220 Joules (optional) for power circuit
Insulation voltageRated 500V per IEC for power circuit
Rated operational voltage200...480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current<10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device listStandard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts1 for auxiliary contacts
High capacity available fault current, max85 kA @ 600V, maximum current 3000 A time delay Class J or Class L fuse for line connected motors
Type of currentAC for auxiliary contacts
Conventional thermal current (Ith)AC/DC: 5 A for auxiliary contacts
Type of control circuitElectromagnetic relay for auxiliary contacts
Type of contactsProgrammable NO/NC for auxiliary contacts
Utilization categoryMG 1 per UL/CSA/NEMA for power circuit
Standard controller featureStatus indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max85 kA @ 690V for maximum FLC
Optional controller featureSMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Integrated motor overload protectionYes
Short circuit protection device performance (SCPD) typeType 1
Number of sensors, max6 for PTC input ratings
Voltage at PTC terminals (RPTC = open), max30V for PTC input ratings
Voltage at PTC terminals (RPTC = 4 kΩ), max<7.5 for PTC input ratings
Transformer rating control module751 VA (recommended 800 VA)
Response time800 ms for PTC input ratings
Cold resistance of PTC sensor chain, max1500 Ohm for PTC input ratings
Tachometer input0...5V DC, 4.5V DC = 100% Speed
Short circuit trip resistance25 Ohm ± 10 Ohm for PTC input ratings
Response resistance3400 Ohm ± 150 Ohm for PTC input ratings
Reset resistance1600 Ohm ± 100 Ohm for PTC input ratings
Input OFF-state voltage, max50V AC, 10V DC/12V AC for control circuit
Input ON-state voltage, min85V AC, 19.2V DC/20.4V AC for control circuit
Rated operational current3 A @ 120V AC, 1.5 A @ 240V AC for auxiliary contacts
Input ON-state current20 mA @ 120V AC/40mA @ 240V AC, 7.6 mA @ 24V AC/DC for control circuit
Contact typeauxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Steady state heat dissipation with control and fan power1222 W
Storage and transportation temperature-20 °C
Humidity5...95% (noncondensing)
Operating temperatureOpen: -5 to 50 °C (23 to 122 °F)
Protection against electrical shockIP00 (open device) per IEC for power circuit
EMC emission levelsRadiated emission: Class A
EMC immunity levelsSurge transient: per EN/IEC 60947-4-2
Altitude2000 m
Pollution degree2
Weight224 kg
ShockOperational: 4 G
Width596.9 mm (23.50 inch)
Depth346.2 mm (13.63 inch)
Height1041.1 mm (41 inch)
Power pole constructionHeatsink hockey puck thyristor modular design
VibrationOperational: 1.0 G peak, 0.15 mm (0.006 inch) displacement
Make3600VA for auxiliary contacts
Break360VA for auxiliary contacts
Internal bypassYes
FunctionSingle direction
Power terminal markingsNEMA, CENELEC EN50 012
Control terminalsClamping yoke connection, M3 screw clamp
Line/load side power terminalsTwo 13.5 mm (0.53 inch) diameter holes per power pole
Number of poles3
EnclosureOpen type
Control modules constructionThermoset and thermoplastic moldings