ROCKWELL AUTOMATION 1756-IF16H
ROCKWELL AUTOMATION 1756-IF16H
ROCKWELL AUTOMATION 1756-IF16H
ROCKWELL AUTOMATIONDisponibile

ControlLogix 16 Pt A/I HART Module

Analog Input - ControlLogix 16 Point HART
Cod. Articolo: 1756-IF16H
Cod. Fornitore: 1756-IF16H
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
Input, currentYes
Input, voltageYes
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Input signal, configurableYes
Output, currentNo
Output, voltageNo
Output signal configurableNo
Analogue inputs configurableYes
Analogue outputs configurableNo
Type of electric connectionScrew-/spring clamp connection
Wire typeCopper
Terminal block torque specifications1756-TBCH: 0.5 Nm (4.4 lb.in)
Input conversion methodSuccessive approximation
Module keyingElectronic, software configurable
Offset drift27 µV/°C
Output conversion methodR-Ladder DAC, monotonicity with no missing codes
Input range0...20 mA, 4...20 mA
Data formatInteger mode (left justified, 2 s complement) IEEE 32-bit floating point
Wire category2 - on signal ports
Overvoltage protection8V DC maximum
Common mode noise rejection>90 dB @ 50/60 Hz (15 Hz and 20 Hz filters only)
Normal mode noise rejection74 dB @ 50/60 Hz (15 Hz filter) 90 dB @ 60 Hz (20 Hz filter)
Module error0.3% of range
Gain drift with temperature11 ppm/°C
Module input scan time, min11...328 ms (filter dependent)
Voltage and current ratingsBackplane: 5.1V DC @ 200 mA, 24V DC @ 125 mA, Input current range: 0...20 mA, 4...20 mA
Total backplane power4.02 W
Thermal dissipation12 BTU/h
Inputs16 differential, current dedicated HART modem per channel
Power dissipation6 W maximum
Resolution16 to 21 Bit
Wire sizeSingle wire connection (1756-TBCH): 0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation maximum, Single wire connection (1756-TBS6H): 0.33...2.1 mm² (22...14 AWG) solid or
Calibrated accuracyBetter than 0.13% of range (all filters)
Open circuit detection timePositive full scale reading within 5 s
Module HART scan timeEstimate 1 s if all channels are HART enabled
Suitable for safety functionsNo
Surrounding air temperature, max60 °C
North American temperature codeT5
EmissionsIEC 61000-6-4
ESD immunity6 kV contact discharges, 8 kV air discharges
EFT/B immunity±2kV at 5 kHz on signal ports
Relative humidity5...95% noncondensing
Conducted RF immunity10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
Surge transient immunity±2 kV line-earth (CM) on shielded signal ports
Operating temperature0 °C
Radiated RF immunity10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Nonoperating temperature-40 °C
RTB keyingUser-defined mechanical
Vibration2 G @ 10...500 Hz
ShockOperating: 30 G, Non operating: 50 G
Slot width1
Calibration interval12 months typical
IEC temperature codeT4
ATEX temperature codeT4
RepeatabilityBetter than 0.01% of range (15 Hz and 20 Hz filters only)
Input impedance249 Ohm
Isolation voltage50V (continuous), basic insulation type, input channels to backplane, No isolation between individual input channels Type tested at 1500V DC for 60 s
Enclosure type ratingNone (open-style)