ROCKWELL AUTOMATION 194E-A100-1756
ROCKWELL AUTOMATION 194E-A100-1756
ROCKWELL AUTOMATIONDisponibile

194E Load switch, 100 A, 6 Poles, OFF-ON 90°, Open, Base/DIN Rail, Standard Terminals, Select actuator separately, Open Switch Style, OFF-ON 90°

IEC Load Switch, Open - Base / DIN Rail, OFF-ON 90°, 100A, 6 Poles
Cod. Articolo: 194E-A100-1756
Cod. Fornitore: 194E-A100-1756
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Conditioned rated short-circuit current Iq25 kA
Rated permanent current Iu100 A
Rated operation power at AC-23, 400 V55 kW
Max. rated operation voltage Ue AC690 V
Rated operation power at AC-3, 400 V37 kW
Rated short-time withstand current lcw2500 kA
Rated frequency60 Hz
Switch size100 A
Lost power per pole5.5 W
Conventional free air thermal current (Ith)120 A per IEC
Conventional enclosed thermal current (Ie)100 A per IEC
Rated operational voltage (Ue)690V per IEC
Rated isolation voltage (Ui)690V per IEC
Continuous currentUL/CSA (applications): 100 A
Rated breaking capacityAC-23A (cosφ 0.45): 800 A @ 400V
Motor FLA ratingUL/CSA application: 84 A @ 120V, 60 Hz, 3 pole, 3 phase
Hp motor ratingUL/CSA application: 7.5 Hp @ 120V, 60 Hz, 1 pole, 1 phase
Fuse rating of circuit (type g, G), maxShort circuit current (co-ordination type 2): 100 A @ 400/415V
Rated current (Ie)DC-21A (for resistive loads): 80 A @ 110V, 2 pole in series, T ≤1 ms, Ue max = 660V
Rated power (Pe)AC-3: 22 kW @ 690V
Number of switches1
Type of electrical connection of main circuitScrew connection
Switching rate120 ops/h
Rated impulse voltage (Uimp)8 kV per UL, CSA
Test voltage (Ui)2.5 kV for 1 minute
Version as emergency stop installationNo
Degree of protection (NEMA)Other
Tightening torque5.6 Nm (50 lb-in)
Switch configurationOFF-ON 90°
Rigid wire gauge4...50 mm2 (10...1 AWG)
Fine strands wire gauge4...35 mm2 (10...1 AWG)
Wire gauge, maxTerminal size per IEC 947-1: A9
Protection class according to IEC 529Switch bodies: IP20 @ motor rating 60 Hz
Actuator typeSelect actuator separately
Version as reversing switchNo
Version as main switchYes
Version as maintenance-/service switchYes
Degree of protection (IP), front sideIP20
Mechanical life operations200000
Device constructionBuilt-in device fixed built-in technique
Switch body height, approx90 mm (3-35/64 inch) @ 100 A
Switch body depth, approx90 mm (3-35/64 inch) @ 100 A
Switch body width, approx144 mm (5-11/16 inch) @ 100 A
InstallationOpen-base/DIN rail
Suitable for distribution board installationNo
Ambient enclosed temperature-20 °C
Ambient storage temperature-40 °C
Ambient operation temperature-25 °C