ROCKWELL AUTOMATION 294E-FD4P2Z-G1
ROCKWELL AUTOMATION 294E-FD4P2Z-G1
ROCKWELL AUTOMATION 294E-FD4P2Z-G1
ROCKWELL AUTOMATIONNon disponibile

Bulletin 294 ArmorStart LT, EtherNet/IP Communications, IP66 UL Type 4/12 Enclosure for 290/291/294,3.6A (1.5 kw) 2.0 hp, 24V DC Separate Control Power, Conduit entry for power and motor

Bulletin 294 ArmorStart LT, EtherNet/IP Communications, IP66 UL Type 4/12 Enclosure for 290/291/294,3.6A (1.5 kw) 2.0 hp, 24V DC Separate Control Power, Conduit entry for power and motor
Cod. Articolo: 294E-FD4P2Z-G1
Cod. Fornitore: 294E-FD4P2Z-G1
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Width381 mm
Height219.32 mm
Depth202.27 mm
Number of polesPower circuit: 3
Wire sizeSource brake: #16 ...#10 AWG (1.0...4.0 mm²) per terminal
Degree of protection (IP)IP66
Shipping weight, approx7.3 kg
Power ratingSource brake: 10 A @ 600V AC
ShockOperational: 30 G, exceeds IEC 60947-1
Gland plate optionsConduit entry for power and motor (no cable)
Wire strip length0.35 ±0.01 inch (9 ±2 mm)
VibrationOperational: 2.5 G @ tested to MIL-STD-810G, exceeds IEC 60947-1
Tightening torqueSource brake: 4.8 ± 2 lb.in (0.5 ± 0.2 Nm)
Mechanical life operationsDisconnect: 200000
Disconnect lock outMaximum of 3/8 inch (9.5 mm) diameter lock shackle or hasp
Wire typeMulti-strand copper wire
Disconnect LOTO locksUp to 2 locks or hasps are supported
Altitude1000 m
Storage and transportation temperature-25 °C
Conducted emissionEN 61800-3, C3
Humidity5...95% noncondensing
Surge transient1 kV (12) L-L, 2 kV (2) L-N (earth)
Radiated emissionsEN 61800-3, C3
Radio frequency electromagnetic fieldEN 55011 Class group 2, 10V/m, 80 MHz...1 GHz
Degree of protection (NEMA)4
Pollution degree3
Radio frequency conducted disturbance immunity10V, 150 kHz...80 MHz
Electrostatic discharge4 kV contact and 8 kV air
Fast transient2 kV (power), 2 kV (PE), 1 kV (communications and control)
Operating temperature-20...40 °C (-4...104 °F), up to 50 °C (122 °F) without derating, when properly rated line reactors are installed in branch circuit
DHCP timeout30 s
Web serverHTTP 1.1
Input ON-state current (pin 4)2.6 mA @ 24V DC
Operating dielectric withstand2000V AC per IEC
Overvoltage categoryPower circuit: III
Fuse ratingUL Class fuse (45 A, maximum)
Consume instance (command)Default of 4 words (instance 154)
Produce instance (status)Default of 16 words (instance 156)
Insulation voltage (Ui)Output ratings: rated 2000V AC per IEC
Faultless power ride throughPower circuit: 10 ms
Rated input operation voltage24V DC
Input OFF-state current<1.5 mA
Input OFF-state voltage5V DC
Operating frequencyPower circuit: 50/60 Hz (±10%)
Rated operating input current, maxPower circuit: 6.5 A @ 400V AC, 50 Hz, 2.0 Hp (1.5 kW)
Trip ratingPower circuit: 200% hardware limit, 300% instantaneous fault
Short circuit coordinationType 1
Overload typePower circuit: 150% for 60 s or 200% for 3 s @ solid-state I^2t
Insulation voltageRated 250V AC
Carrier frequencyPower circuit: 2...10 kHz, drive rating based on 4 kHz
Speed regulation - open loop with slip compensationPower circuit: ±2% of base speed across a 40:1 speed range
Dielectric withstandPower circuit: 2500V AC per IEC
Concurrent TCP connectionsNetwork connections: maximum of 5 encapsulated messages over both TCP and UDP
RMS symmetrical amperes5 kA @ 480Y/277 (short circuit current rating)
PowerControl circuit (external source): 6.6 W @ switched and unswitched power supply requirements
Current, nomControl circuit (external source): 275 mA @ switched and unswitched power supply requirements
Peak inrushControl circuit (external source): <5 A for 35 ms @ unswitched power supply requirements
VoltageControl circuit (external source): 19.2...26.4V DC @ unswitched power supply requirements
Trip classPower circuit: Class 10 protection with speed sensitive response and power-down overload retention function
Current, maxControl circuit (external source): 450 mA @ unswitched power supply requirements
Power, maxControl circuit (external source): 6.6 W + (24V DC x user defined) @ switched and unswitched power supply requirements
Over voltagePower circuit: 380...480V AC input - trip occurs at 810V DC bus voltage (equivalent to 575V AC incoming line)
Under voltagePower circuit: 380...480V AC Input - trip occurs at 390V DC bus voltage (equivalent to 275V AC incoming line)
Stop modesPower circuit: multiple programmable stop modes including, ramp, coast, DC-brake, ramp to hold, and S-curve
DataTransported over both TCP and UDP
Acceleration/decelerationPower circuit: two independently programmable acceleration and deceleration times. Each time can be programmed from 0...600 s in 0.1 s increments.
Application in industrial area permittedYes
Max. output frequency400 Hz
Supporting protocol for EtherNet/IPYes
Mains frequency50/60 Hz
Number of input devices, max6
Output OFF-state leakage current, max1 μA
Number of outputs, max6
Input filtering100 µs
Sockets, max150
Output supply voltage (switched power)A1/A2
Input per connection1/each
Output per connection1/each
Output blocking voltage, max35V DC
Sensor input leakage current, max<2.5 mA
Type of outputsDC sourcing
Sensor input operating voltage19.2...26V DC
Concurrent sessionsWeb server: 20
Rated output operating voltage (Ue)19.2...26.4V DC
Output operating current (Ie), nom500 mA per point
Output thermal current (Ithe), max500 mA per point
Output stateNormally open (NO)
Rated impulse voltage (Uimp)Power circuit: 4 kV
Output utilization categoryDC-1, DC-13 per IEC
Ethernet ports2 (embedded switch)
Message supportUnicast or multicast
Input ON-state voltage (pin 4), nom10...26.4V DC, 24V DC
IP configurationStatic, DHCP or BOOTP
Input supply voltageUnswitched power A3/A2
Type of inputs24V DC current sinking
Concurrent explicit messages, max (CIP Class 3)Network connections: 6
Input power terminalsPower circuit: L1, L2, L3
Motor power terminalsPower circuit: T1, T2, T3
ApplicationPower circuit: three-phase
Ethernet network topologies supportedStar, tree, linear and ring
EfficiencyPower circuit: 97.5% typical
DeviceLogix I/O responseInput ratings: 2 ms @ 500 Hz
Output load typesResistive or light inductive
PE (earth ground) terminalPower circuit: 4 PE terminals
Reset modePower circuit: automatic/manual
Input bounce filter (software configurable)OFF-ON or ON-OFF: 0.5 ms + 64 ms
Ethernet communication rate10/100 Mbps, half or full-duplex
Class 1 connection APINetwork connections: 2...3200 ms
Input connection typeSingle keyed M12, quick disconnect
Output connection typeSingle keyed M12, quick disconnect
Ethernet cableCategory 5e: shielded or unshielded
Class 3 connection APINetwork connections: 100...10000 ms
Output frequencyPower circuit: 0...400 Hz programmable
Source brake (EM brake) currentPower circuit: maximum load current of 3 A
SecurityWeb server: login and password configurable
Motor control typePower circuit: slip compensation (Volts/Hz)
Power supplyControl circuit (external source): NEC Class 2
Rated operating voltage, maxPower circuit: 400Y/230...480Y/277 (-15%, +10%)
Device level ring supportBeacon performance, IEEE 1588 transparent clock
Ethernet connectorM12, D code, female, with Ethernet keying, 4 pin
Request packet interval (RPI)Network connections: 20 ms default (2 ms minimum)
Rated operating voltageControl circuit (external source): 24V DC (+10%, -20%)
Webpage featuresWeb server: status, diagnostics and configuration tabs
Output overcurrent protection1.5 A (the sum of all outputs cannot exceed this value)
E-mailWeb server: support simple mail transfer protocol (SMTP)
Output surge suppressionIntegrated diode to help protect against switching loads
EtherNet/IP ODVA âۉ€œ conformance testingEtherNet/IP interoperability performance âۉ€œ per A9 PF 2.1
Address conflict detection (ACD)IP v4 address conflict detection for EtherNet/IP devices
Overvoltage protectionControl circuit (external source): reverse-polarity protected
Sensor sourcing input current (pin 1), max50 mA per point (maximum 300 mA total for sourcing one device)
Control ride throughPower circuit: minimum ride through is 0.5 s - typical value is 2 s
Motor control featuresPower circuit: flying start, V/F ratio, bus regulator, 4 preset speeds
Packet rate (pps)500 packets-per-second (2000 μs), Tx, 500 packets-per-second (2000 μs), Rx
Output current (each)Control circuit (external source): 500 mA @ switched power supply requirements
Input current (each)Control circuit (external source): 50 mA @ unswitched power supply requirements
Motor cable length, maxPower circuit: 10 m (32 ft)(CE application), Power circuit: 14 m (45.9 ft) (non-CE application)
Number of inputs (x 50 mA)Control circuit (external source): user defined @ switched and unswitched power supply requirements
Number of outputs (x 500 mA)Control circuit (external source): user defined @ switched and unswitched power supply requirements
IPS optionControl circuit (internal source): an internal 50 W power supply sources 24V DC for input, outputs and logic control (3-phase line power of 400Y/230V...480Y/277V, 50/60 Hz is required)
I/O connections, max (CIP Class 1)Network connections: supports up to 2 class 1 CIP connections [exclusive owner (data) or listen-only]. One connection per PLC. Listen only connection requires a data connection to be established.
Specifiche
Specifications
Type:EtherNet/IP Communications
Enclosure:IP66, UL Type 4/12 Enclosure for 290/291/294
kW:1.5 kW
Hp:2 Hp
Voltage Rating:24V DC Separate Control Power
System Data
Supply Voltage:380Y/220V...480Y/277V AC
Module Data
Communications:EtherNet/IP Communications
Enclosure Type:IP66, UL Type 4/12 Enclosure for 290/291/294
Output Current:3.6A (1.5 kw) 2.0 hp
Control Voltage:24V DC Separate Control Power
Gland Plate Options:Conduit entry for power and motor