ROCKWELL AUTOMATION 5069-OF8
ROCKWELL AUTOMATION 5069-OF8
ROCKWELL AUTOMATION 5069-OF8
ROCKWELL AUTOMATIONDisponibile

Compact 5000 Analog Output Module

5069 Compact I/O 8 Channel Voltage/Current Analog Output Module
Cod. Articolo: 5069-OF8
Cod. Fornitore: 5069-OF8
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
Number of analogue outputs8
Input, currentNo
Input, voltageNo
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Output, currentYes
Output, voltageYes
Analogue inputs configurableNo
Analogue outputs configurableYes
Type of electric connectionScrew-/spring clamp connection
Capacitive load, max1 μF (voltage mode only)
Inductive load, max1 mH (current mode only)
Module keyingElectronic keying via programming software
Scan timePer group 0...3: 1 ms, Per group 0...7: 2 ms
Step response time to 63% of valueVoltage mode: 18 μs max, Current mode: 1 ms max
Module conversion methodR-Ladder DAC, monotonicity with no missing codes
Outputs8 voltage or current
Open circuit detectionCurrent mode only
Drive capabilityVoltage: 1000 Ω minimum, Current: 500 Ω maximum
RTB torque5069-RTB18-SCREW RTB only: 0.4 Nm (3.5 lbin)
Overvoltage protection, max±32V DC
Short circuit detectionVoltage mode only – output electronically limited to 16 mA or less
Data formatIEEE 32-bit floating point
Wire category2 - shielded input ports, 2 - power ports, 1 wire per terminal for each signal port
Power dissipation, max5.3 W
Indicators1 green/red module status indicator, 8 yellow/red I/O status indicators
Thermal dissipation, max18.1 BTU/hr
Accuracy drift with temperatureVoltage: 0.30% full scale, Current: 0.50% full scale
Resolution16 bits across ±10.5V - 320 μV/bit, 16 bits across 10.5V - 160 μV/bit, 16 bits across 5.25V - 80 μV/bit, 16 bits across 21 mA - 320 nA/bit
Wire size5069-RTB18-SPRING removable terminal block: 0.5...1.5 mm² (22...16 AWG) solid or stranded copper wire rated at 105 °C (221 °F), or greater, 2.9 mm (0.11 in.), max diameter including insulation, 5069-RTB18-SCREW removable terminal block: 0.5...1.5 mm² (22.
Calibrated accuracyVoltage: 0.10% full scale @ 25 °C Current: 0.10% full scale @ 25 °C
Suitable for safety functionsNo
Repeatability0.05 %
Conversion timePer channel: 25 µs
Output range, current0...20 mA, 4...20 mA
Output range, voltage±10V, 0...10V, 0...5V
Calibration methodsFactory calibrated, User-performed (optional)
Insulation stripping length5069-RTB18-SPRING connections: 10 mm (0.39 in.), 5069-RTB18-SCREW connections: 12 mm (0.47 in.)
Width22 mm
Height144.57 mm
Depth105.42 mm
Enclosure typeNone (open-style)
Surrounding air temperature, max60 °C
North American temperature codeT4
Operating temperature0 °C
EmissionsIEC 61000-6-4
ESD immunity6 kV contact discharges, 8 kV air discharges
EFT/B immunity±4 kV @ 5 kHz on power ports, ±3 kV @ 5 kHz on shielded output ports
Relative humidity5...95% noncondensing
Conducted RF immunity10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Surge transient immunity±1 kV line-line (DM) and ±2 kV line-earth (CM) on power ports, ±2 kV line-earth (CM) on shielded output ports
Radiated RF immunity10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Nonoperating temperature-40 °C
Voltage variation10 ms interruption on MOD power port
SA power250 mA @ 18...32V DC
SA power passthrough, max9.95 A @ 18...32V DC
MOD power75 mA @ 18...32V DC
MOD power passthrough, max9.55 A @ 18...32V DC
Analog output ratings±10V DC @ 0...20 mA per channel
RTB keyingNone
Weight175 g
Vibration5 G @ 10...500 Hz
ShockOperating: 30 G, Non operating: 50 G
Slot width1
DIN railCompatible zinc-plated chromate-passivated steel DIN rail, You can use the EN50022 - 35 x 7.5 mm (1.38 x 0.30 in) DIN rail
Isolation voltage250V (continuous), basic insulation type, 50V Functional isolation between SA power and input ports, No isolation between individual input ports
ATEX temp codeT4
IECEx temp codeT4