800H PB, Type 7&9 Selector Switch, 2 Position Selector Switch, KB6 Cam, Standard KB7 Cam, None, 1-NO 1-NC Standard Contacts, No Block This Position, No Block This Position, No Block This Position, D018 (Std. Key), No Guards - on Terminals, Maint., Lock -

Hazardous Location Type 7&9 2 Pos. Cyl. Lock Sel. Switch, Standard Barrel Length, Maint., Key Removal - Left, D018 (Std. Key), 1 NO-1 NC
Cod. Articolo: 800H-HP31KB6AXXX
Cod. Fornitore: 800H-HP31KB6AXXX
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
Number of switch positions2
Spring-returnNo
With light sourceNo
Switching function latchingYes
Hole diameter30.5 mm
Type of electric connectionScrew connection
Typical operating forces with contact blocks800T-XA: 1 lb
Mechanical life operations200000 minute
Number of positions2-position selector switch
Shock1/2 cycle sine wave for 11 ms ≥25 G (contact fragility) and no damage at 100 G
Vibration10...2000 Hz, 1.52 mm displacement (peak-to-peak) maximum/10 G maximum (except Logic Reed)
Terminal screw torque6 lb.in
Typical operating forces operator without contact blocksMaintained selector switch: 4 inch-lb maximum
Degree of protectionType 7 & 9 explosion proof (Type 3 and Type 4 ratings available with accessories)
Number of contacts as normally closed contact1
Number of contacts as normally open contact1
Suitable for illuminationNo
Operational voltage (Ue), max600V AC, 600V DC
Thermal continuous current (Ith), max10 A AC, 2.5 A DC
Rated operational current69VA @ 28...600V DC
Rated operational current, break720VA @ 72...120V AC
Rated operational current, make7200VA @ 120...600V AC
Contact operationSlow, double make and break
Utilization categoryAC-15 per IEC, DC-13 per IEC
Position 2 contact blockNo block this position
Position 1 contact block1 NO, 1 NC, standard contact block (800T-XA)
Position 3 contact blockNo block this position
Position 4 contact blockNo block this position
Wire gauge18 to 14 AWG
Dielectric strength2200V for 1 minute, 1300V for 1 minute (Logic Reed)
Electrical life cycle1000000 cycles at maximum rated load, 200000 cycles at maximum rated load (Logic Reed)
Material front ringPlastic
Type of control elementKey
2-position cam optionsKB6 cam
Key optionsD018 (standard key)
Finger-safe guardsNo guards on terminals
2-position lock/functionMaintained, lock in left position, standard key
With front ringYes
Operating temperature-20 °C
Humidity50% at 104 °F (40 °C)
Storage temperature-40 °C