SICK 1062988
SICKNon disponibile

PAC50-DGF

Pressure sensors: PAC50
Cod. Articolo: 1062988
Cod. Fornitore: 1062988
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
MediumDry compressed air
Pressure typeGauge pressure
Pressure unitbar
Measuring range0 bar ... 10 bar
Overpressure safety15 bar
Process temperature0 °C ... +60 °C
Analog signal output and ohmic load RA

Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA ... 4 mA / 10 V ... 0 V

Load resistance for current output < 600 Ohm

Load resistance with current output > 3 kOhm

Zero point adjustmentMax. + 5 % of span
Output signalIO-Link/PNP + PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V ... 10 V
Diagnostics outputSwitching output 2 can be set as diagnostics output
Display

LCD with LED backlight (green/red), can be rotated electronically by 180°

Pressure display: 4 digits, 16 segments

Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg

Update: 1,000, 500, 200, 100 ms (adjustable)

Initialization time300 ms
Mechanics/electronics
Process connection2 x G ¼ 
Housing materialHousing: polycarbonate, Buttons: TPE, DIN rail mounting: POM, seals: NBR
Connection typeRound connector M12 x 1, 5-pin
Supply voltage17 V DC ... 30 V DC
Power consumptionMax. 40 mA at L+ = 24 VDC
Electrical safety

Protection class: III

Overvoltage protection: 32 V DC

Short-circuit protection: QA, Q1, Q2 towards M and L+

Reverse polarity protection: L+ to M

CE-conformityEMC directive: 2004/108/EC, EN 61326-2-3
Weight sensorApprox. 40 g
Enclosure rating

IP65 

IP67 

Protection class III
RoHS certificate
cRUus certificate
Performance
Non-linearity≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
Accuracy≤ ± 1.5 % of the span
Setting accuracy of switching outputs≤ ± 0.2 % of span
Non-repeatability≤ ± 0.2 % of the span
Rated temperature range+10 °C ... +60 °C
Ambient data
Ambient temperature0 °C ... +60 °C
Storage temperature–20 °C ... +80 °C
Relative humidity≤ 90 %
Shock loadMax. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock)
Vibration loadMax. 5 g (10 ... 150 Hz), xyz, to DIN EN 60068-2-6
Classifications
eCl@ss 5.027200620
eCl@ss 5.1.427200620
eCl@ss 6.027200620
eCl@ss 6.227200620
eCl@ss 7.027200620
eCl@ss 8.027200620
eCl@ss 8.127200620
eCl@ss 9.027200620
eCl@ss 10.027200620
eCl@ss 11.027200620
eCl@ss 12.027200620
ETIM 5.0EC000243
ETIM 6.0EC000243
ETIM 7.0EC000243
ETIM 8.0EC000243
UNSPSC 16.090141112409
Specifiche
Unit weight0.161 Kilograms
Net unit weight0.161 Kilograms
Unit volume468.75 Cubic Centimetres (cm³)
Measurements7.500*5.000*12.500
Country of originThailand
EAN4047084435515