Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

SICK 1097648
SICKNon disponibile

IMS18-12NPOVC0S

Inductive proximity sensors: IMS
Cod. Articolo: 1097648
Cod. Fornitore: 1097648
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
HousingCylindrical thread design
HousingStandard design
Thread sizeM18 x 1
DiameterØ 18 mm
Sensing range Sn12 mm
Safe sensing range Sa9.72 mm
Installation typeNon-flush
Switching frequency900 Hz
Connection typeMale connector M12, 4-pin 
Switching outputPNP
Output functionNC
Electrical wiringDC 3-wire
Enclosure rating

IP68 

IP69K 

Special featuresResistant against coolant lubricants, Temperature resistance
Special applicationsMobile machines, Zones with coolants and lubricants, Difficult application conditions
Items suppliedMounting nut, brass, nickel-plated (2x)
Mechanics/electronics
Supply voltage7.2 V DC ... 60 V DC
Ripple≤ 10 %
Voltage drop≤ 2.5 V 
Time delay before availability100 ms
Hysteresis3 % ... 20 %
Reproducibility≤ 2 % 
Temperature drift (of Sr)± 10 %
EMC

Emitted interference and interference immunity in accordance with Motor Insurance Directive ECE-R10 Rev. 5: E1-Type approval

Interference immunity in accordance with DIN ISO 11452-2: 100 V/m

AM vertical 20 MHz - 800 MHz; AM horizontal 200 MHz - 800 MHz; PM vertical/horizontal 800 MHz - 2.7 GHz

Conducted disturbances in accordance with ISO 7637-2 (pulse/severity/failure criterion 12 V/failure criterion 24 V): 1/IV/C/C, 2a/IV/A/A, 2b/IV/C/C, 3a/IV/A/A, 3b/IV/A/A, 4/IV/C/A, 5a/IV/B/B, 5b/IV/B/B

EN 61000-4-2 ESD: 4 kV CD / 8 kV AD

EN 61000-4-3 HF radiated: 10 V/m

EN 61000-4-4 burst: 2 kV

EN 61000-4-5 surge: 0,5 kV L-to-L, Ri: 2 Ohm

EN 61000-4-6 HF wire-bound: 10 V

Environmental testQuick temperature change EN 60068-2-14, Na: TA = –25 °C, TB = 75 °C, t1 = 40 min, t2 = < 10 s, 300 cycles, Delta Sr ≤ 10%
Corrosion testSalt spray test EN 60068-2-52: severity 5, 4 cycles
Continuous current Ia≤ 200 mA 
No load current≤ 10 mA
Short-circuit protection
Reverse polarity protection
Power-up pulse protection
Shock and vibration resistance

Vibration resistance EN 60068-2-6 Fc: 25 g peak (10 Hz ... 2,000 Hz) / –20 °C ... +50 °C

Shock resistance EN 60068-2-27 Ea: 100 g 11 ms; 3 shocks in every direction of the 3 coordinate axes / –40 °C ... +85 °C

Continuous shock resistance EN 60068-2-29 Eb: 40 g 3 ms rise, 7 ms fall / 5,000 shocks in every direction of the 3 coordinate axes / -20 °C ... +50 °C

Broadband noise EN 60068-2-64: 15 g rms (5 Hz ... 2,000 Hz) / 8 hours in every direction of the 3 coordinate axes / –40 °C ... +85 °C

Ambient operating temperature–40 °C ... +100 °C
Housing materialStainless steel V2A, DIN 1.4305 / AISI 303
Sensing face materialPlastic, LCP
Housing length69 mm
Thread length43 mm
Tightening torque, max.Typ. 60 Nm
Protection classIII
UL File No.E181493
Safety-related parameters
MTTFD1,196 years
DCavg0 %
Reduction factors
NoteThe values are reference values which may vary
Stainless steel (V2A, 304)Approx. 0.7
Aluminum (Al)Approx. 0.43
Copper (Cu)Approx. 0.37
Brass (Br)Approx. 0.43
Installation note
RemarkAssociated graphic see "Installation"
A18 mm
B45 mm
C18 mm
D36 mm
E12 mm
F96 mm
Classifications
ECLASS 5.027270101
ECLASS 5.1.427270101
ECLASS 6.027270101
ECLASS 6.227270101
ECLASS 7.027270101
ECLASS 8.027270101
ECLASS 8.127270101
ECLASS 9.027270101
ECLASS 10.027270101
ECLASS 11.027270101
ECLASS 12.027274001
ETIM 5.0EC002714
ETIM 6.0EC002714
ETIM 7.0EC002714
ETIM 8.0EC002714
UNSPSC 16.090139122230
Specifiche
Unit weight68.000 Grams
Net unit weight68 Grams
Unit volume300 Cubic Centimetres (cm³)
Measurements15.000*1.000*20.000
Country of originHungary
EAN4047084471001