Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

SICK 5325922
SICKNon disponibile

LL3-TV08 LIGHT GUIDE CYLINDR. TYPE

Fiber-optic sensors and fibers: LL3
Cod. Articolo: 5325922
Cod. Fornitore: 5325922
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
Device typeFibers
Functional principleThrough-beam system
Functional principle detailConsisting of a sender and a receiver
For fiber-optic sensorGLL170(T), WLL180, WLL24 Ex, WLL80
Fiber length2,000 mm
Fiber materialPolymethylmethacrylat (PMMA)
Jacket materialPolyethylen (PE)
Fiber head materialStainless steel
Outer diameter, fiber-optic cable connection2.2 mm
Fiber-optic cable cuttable
Smooth sleeve diameter (greatest diameter)2 mm
Fiber-optic head designSmooth sleeve, Long end sleeve, 90° deflection
Fiber arrangementMonofiber
Core structureØ 1,0 mm Monofiber
Angle of dispersion < 60°Yes
Compatibility with infrared light (1,450 nm)No
Diameter/thread size from 2 mm taper≥ 1 mm
Length of taper≥ 15 mm
Diameter of taper≥ 1 mm
Highly flexible/elastic fibers (bend radius 1–4 mm)No
Adapter end sleeves requiredNo
Angle of dispersion6.87°
Integrated lensYes
Minimal object diameter0.05 mm 
Included with deliveryFC fiber cutter (5304141)
Compatibility tip adaptersNo
Mechanics/electronics
Bend radius, fibre-optic cable25 mm
Ambient operating temperature–40 °C ... +60 °C
Classifications
ECLASS 5.027270905
ECLASS 5.1.427270905
ECLASS 6.027270905
ECLASS 6.227270905
ECLASS 7.027270905
ECLASS 8.027270905
ECLASS 8.127270905
ECLASS 9.027270905
ECLASS 10.027270905
ECLASS 11.027270905
ECLASS 12.027270905
ETIM 5.0EC002651
ETIM 6.0EC002651
ETIM 7.0EC002651
ETIM 8.0EC002651
UNSPSC 16.090139121528
Sensing ranges with WLL80
Operating mode 16 µs1,280 mm
Operating mode 70 µs3,600 mm
Operating mode 250 µs3,600 mm
Operating mode 500 µs3,600 mm
Operating mode 1 ms3,600 mm
Operating mode 2 ms3,600 mm
Operating mode 8 ms3,600 mm
Sensing ranges with WLL180T
Operating mode 16 µs590 mm
Operating mode 70 µs1,790 mm
Operating mode 250 µs2,400 mm
Operating mode 2 ms4,000 mm
Operating mode 8 ms4,000 mm
NoteSensing ranges related to fiber-optic sensors with type of light: visible red light
Sensing ranges with GLL170
Operating mode 250 µs1,690 mm
Sensing ranges with GLL170T
Operating mode 50 µs1,760 mm
Operating mode 250 µs2,060 mm
Specifiche
Unit weight51.000 Grams
Net unit weight51 Grams
Unit volume510.6 Cubic Centimetres (cm³)
Measurements14.800*2.300*15.000
Country of originJapan