Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

SICK 5325971
SICKNon disponibile

LL3-TH11 LIGHT GUIDE HEAT RESIST.

Fiber-optic sensors and fibers: LL3
Cod. Articolo: 5325971
Cod. Fornitore: 5325971
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
Device typeFibers
Functional principleThrough-beam system
Functional principle detailConsisting of a sender and a receiver
For fiber-optic sensorGLL170(T), WLL180, WLL80
Fiber length1,000 mm
Fiber materialGlass
Jacket materialSilicium (Si)
Fiber head materialCopper-zinc alloy (CuZn)
Outer diameter, fiber-optic cable connection2.2 mm
Thread diameter (housing)M4
Fiber-optic head designThreaded sleeve
Fiber arrangementMonofiber
Core structureØ 1,1 mm Monofiber
Angle of dispersion < 60°No
Compatibility with infrared light (1,450 nm)Yes 
ApplicationHeat-resistant (≥100°C)
Diameter/thread size from 2 mm taper≥ 2.6 mm
Length of taper≥ 3 mm
Highly flexible/elastic fibers (bend radius 1–4 mm)No
Adapter end sleeves requiredNo
Angle of dispersion60°
Integrated lensNo
Minimal object diameter0.04 mm 
Included with deliveryMounting, 4 x M4 hexagon nut, 2 x washer
Compatibility tip adaptersYes
Mechanics/electronics
Bend radius, fibre-optic cable25 mm
Ambient operating temperature–60 °C ... +200 °C
Classifications
ECLASS 5.027270905
ECLASS 5.1.427270905
ECLASS 6.027270905
ECLASS 6.227270905
ECLASS 7.027270905
ECLASS 8.027270905
ECLASS 8.127270905
ECLASS 9.027270905
ECLASS 10.027270905
ECLASS 11.027270905
ECLASS 12.027270905
ETIM 5.0EC002651
ETIM 6.0EC002651
ETIM 7.0EC002651
ETIM 8.0EC002651
UNSPSC 16.090139121528
Sensing ranges with WLL80
Operating mode 16 µs275 mm
Operating mode 70 µs825 mm
Operating mode 250 µs1,310 mm
Operating mode 500 µs1,600 mm
Operating mode 1 ms1,600 mm
Operating mode 2 ms1,600 mm
Operating mode 8 ms1,600 mm
Sensing ranges with WLL180T
Operating mode 16 µs130 mm
Operating mode 70 µs400 mm
Operating mode 250 µs700 mm
Operating mode 2 ms1,400 mm
Operating mode 8 ms1,500 mm
NoteSensing ranges related to fiber-optic sensors with type of light: visible red light
Sensing ranges with GLL170
Operating mode 250 µs410 mm
Sensing ranges with GLL170T
Operating mode 50 µs400 mm
Operating mode 250 µs620 mm
Specifiche
Unit weight59.100 Grams
Net unit weight59.1 Grams
Unit volume450 Cubic Centimetres (cm³)
Measurements15.000*2.000*15.000
Country of originJapan