SICK 5325975
SICKNon disponibile

LL3-TH15 LIGHT GUIDE HEAT RESIST.

Fiber-optic sensors and fibers: LL3
Cod. Articolo: 5325975
Cod. Fornitore: 5325975
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
Device typeFibers
Functional principleThrough-beam system
Functional principle detailConsisting of a sender and a receiver
For fiber-optic sensorGLL170(T), WLL180, WLL80
Fiber length2,000 mm
Fiber materialGlass
Jacket materialStainless steel
Fiber head materialCopper-zinc alloy (CuZn)
Outer diameter, fiber-optic cable connection2.2 mm
Smooth sleeve diameter (greatest diameter)4 mm
Fiber-optic head designSmooth sleeve, 90° deflection
Fiber arrangementMonofiber
Core structureØ 0,8 mm Monofiber
Angle of dispersion < 60°No
Compatibility with infrared light (1,450 nm)Yes 
ApplicationHeat-resistant (≥100°C)
Highly flexible/elastic fibers (bend radius 1–4 mm)No
Adapter end sleeves requiredNo
Angle of dispersion60.23°
Integrated lensYes
Minimal object diameter0.16 mm 
Included with deliveryMounting, 2 x M4 hexagon nut, 2 x M4 hexagon nut (plastic), 2 x washer, FC fiber cutter (5304141), LL3-TB09
Compatibility tip adaptersNo
Mechanics/electronics
Bend radius, fibre-optic cable25 mm
Ambient operating temperature–60 °C ... +200 °C
Classifications
ECLASS 5.027270905
ECLASS 5.1.427270905
ECLASS 6.027270905
ECLASS 6.227270905
ECLASS 7.027270905
ECLASS 8.027270905
ECLASS 8.127270905
ECLASS 9.027270905
ECLASS 10.027270905
ECLASS 11.027270905
ECLASS 12.027270905
ETIM 5.0EC002651
ETIM 6.0EC002651
ETIM 7.0EC002651
ETIM 8.0EC002651
UNSPSC 16.090139121528
Sensing ranges with WLL80
Operating mode 16 µs190 mm
Operating mode 70 µs565 mm
Operating mode 250 µs895 mm
Operating mode 500 µs1,105 mm
Operating mode 1 ms1,305 mm
Operating mode 2 ms1,715 mm
Operating mode 8 ms2,490 mm
Sensing ranges with WLL180T
Operating mode 16 µs90 mm
Operating mode 70 µs290 mm
Operating mode 250 µs480 mm
Operating mode 2 ms970 mm
Operating mode 8 ms1,000 mm
NoteSensing ranges related to fiber-optic sensors with type of light: visible red light
Sensing ranges with GLL170
Operating mode 250 µs270 mm
Sensing ranges with GLL170T
Operating mode 50 µs290 mm
Operating mode 250 µs410 mm
Specifiche
Unit weight0.102 Kilograms
Net unit weight0.102 Kilograms
Unit volume912.025 Cubic Centimetres (cm³)
Measurements19.100*2.500*19.100
Country of originJapan