Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

SICK 5326022
SICKNon disponibile

LL3-DH04 LIGHT GUIDE HEAT RESIST.

Fiber-optic sensors and fibers: LL3
Cod. Articolo: 5326022
Cod. Fornitore: 5326022
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Caratteristiche Tecniche
Features
Device typeFibers
Functional principleProximity system
For fiber-optic sensorGLL170(T), WLL180, WLL80
Fiber length2,000 mm
Fiber materialGlass
Jacket materialStainless steel
Fiber head materialStainless steel
Outer diameter, fiber-optic cable connection2.2 mm
Thread diameter (housing)M6
Fiber-optic head designThreaded sleeve, Long end sleeve, Bendable sleeve
Array width8.75 mm
Fiber arrangementMulti-fiber – fiber bundle
Core structureS: 380 x Ø 0,5 µm R: 380 x Ø 0,5 µm Multi-fiber – fiber bundle
Angle of dispersion < 60°No
Compatibility with infrared light (1,450 nm)Yes 
ApplicationHeat-resistant (≥100°C)
Diameter/thread size from 2 mm taper≥ 2.8 mm
Length of taper≥ 60 mm
Diameter of taper≥ 2.8 mm
Highly flexible/elastic fibers (bend radius 1–4 mm)No
Adapter end sleeves requiredNo
Angle of dispersion60°
Integrated lensNo
Minimum bend radius of end sleeve10 mm
Minimal object diameter0.02 mm 
Included with deliveryMounting, 2 x M6 hexagon nut, 1 x washer
Compatibility tip adaptersNo
Mechanics/electronics
Bend radius, fibre-optic cable25 mm
Bend radius, end sleeve10 mm
Ambient operating temperature–30 °C ... +350 °C
Classifications
ECLASS 5.027270905
ECLASS 5.1.427270905
ECLASS 6.027270905
ECLASS 6.227270905
ECLASS 7.027270905
ECLASS 8.027270905
ECLASS 8.127270905
ECLASS 9.027270905
ECLASS 10.027270905
ECLASS 11.027270905
ECLASS 12.027270905
ETIM 5.0EC002651
ETIM 6.0EC002651
ETIM 7.0EC002651
ETIM 8.0EC002651
UNSPSC 16.090139121528
Sensing ranges with WLL80
Operating mode 16 µs120 mm
Operating mode 70 µs300 mm
Operating mode 250 µs500 mm
Operating mode 500 µs595 mm
Operating mode 1 ms665 mm
Operating mode 2 ms900 mm
Operating mode 8 ms1,090 mm
Sensing ranges with WLL180T
Operating mode 16 µs65 mm
Operating mode 70 µs225 mm
Operating mode 250 µs500 mm
Operating mode 2 ms1,000 mm
Operating mode 8 ms1,060 mm
NoteSensing ranges related to fiber-optic sensors with type of light: visible red light
Sensing ranges with GLL170
Operating mode 250 µs150 mm
Sensing ranges with GLL170T
Operating mode 50 µs150 mm
Operating mode 250 µs360 mm