LL3-DH06 LIGHT GUIDE HEAT RESIST.

Fiber-optic sensors and fibers: LL3
Cod. Articolo: 5326026
Cod. Fornitore: 5326026
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
Device typeFibers
Functional principleProximity system
For fiber-optic sensorGLL170(T), WLL180
Fiber length2,000 mm
Fiber materialGlass
Jacket materialStainless steel
Fiber head materialStainless steel
Outer diameter, fiber-optic cable connection2.2 mm
Fiber-optic head designFlat type, 90° deflection
Fiber arrangementMonofiber
Core structure2 x Ø 1,2 mm Monofiber
Angle of dispersion < 60°No
Compatibility with infrared light (1,450 nm)Yes 
ApplicationLcd / clear material / semiconductor
Highly flexible/elastic fibers (bend radius 1–4 mm)No
Adapter end sleeves requiredNo
Angle of dispersion80.73°
Integrated lensYes
Minimal object diameter0.02 mm 
Compatibility tip adaptersNo
Mechanics/electronics
Bend radius, fibre-optic cable25 mm
Ambient operating temperature–30 °C ... +300 °C
Classifications
ECLASS 5.027270905
ECLASS 5.1.427270905
ECLASS 6.027270905
ECLASS 6.227270905
ECLASS 7.027270905
ECLASS 8.027270905
ECLASS 8.127270905
ECLASS 9.027270905
ECLASS 10.027270905
ECLASS 11.027270905
ECLASS 12.027270905
ETIM 5.0EC002651
ETIM 6.0EC002651
ETIM 7.0EC002651
ETIM 8.0EC002651
UNSPSC 16.090139121528
Sensing ranges with WLL80
Operating mode 16 µs0 mm ... 14 mm
Operating mode 70 µs0 mm ... 41 mm
Operating mode 250 µs0 mm ... 55 mm
Operating mode 500 µs0 mm ... 60 mm
Operating mode 1 ms0 mm ... 66 mm
Operating mode 2 ms0 mm ... 70 mm
Operating mode 8 ms0 mm ... 76 mm
Sensing ranges with WLL180T
Operating mode 16 µs3 mm ... 5 mm
Operating mode 70 µs0 mm ... 10 mm
Operating mode 250 µs0 mm ... 19 mm
Operating mode 2 ms0 mm ... 37 mm
Operating mode 8 ms0 mm ... 43 mm
NoteSensing ranges related to fiber-optic sensors with type of light: visible red light
Sensing ranges with GLL170
Operating mode 250 µs0 mm ... 14 mm
Sensing ranges with GLL170T
Operating mode 50 µs0 mm ... 19.5 mm
Operating mode 250 µs0 mm ... 30 mm
Specifiche
Unit weight0.100 Grams
Net unit weight0.1 Grams
Unit volume450 Cubic Centimetres (cm³)
Measurements15.000*2.000*15.000
Country of originJapan