PBSH-RB2X5SHGEENMA0Z

Pressure sensors: PBS Hygienic
Cod. Articolo: 6051879
Cod. Fornitore: 6051879
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
MediumLiquid, gaseous
Pressure typeGauge pressure
Pressure unitbar
Measuring range0 bar ... 2.5 bar
Overpressure safety2-fold
Process temperature–20 °C ... +125 °C, +150 °C for max. 1 h
Maximum ohmic load RA

≤ 0.5 kΩ, 4 mA ... 20 mA (RA ≤ 0.5 kOhm)

0 V ... 10 V (RA > 10 kOhm)

Zero point adjustmentMax. + 3 % of span
Output signalIO-Link/PNP + 4 mA ... 20 mA
Rotatable housing

Display against housing with electrical connection: 330 °

Housing against process connection: 320 °

Display

14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°

Accuracy: ≤ 1 % of span ± 1 digit

Update: 1,000, 500, 200, 100 ms (adjustable)

Mechanics/electronics
Process connectionG 1 hygienic flush-mounted
Wetted partsStainless steel 1.4435 / 316L
Internal transmission fluidMedical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP
Housing materialLower body: stainless steel 304, Plastic head: PC + ABS, Buttons: TPE-E, Display window: PC
Connection typeM12 round connector x 1, 4-pin
Supply voltage15 V DC ... 35 V DC
Power consumptionMax. 70 mA
Total current consumptionMax. 170 mA (incl. switching current)
Electrical safety

Protection class: III

Overvoltage protection: 40 V DC

Short-circuit protection: QA, Q1, Q2 towards M

Reverse polarity protection: L+ to M

Isolation voltage500 V DC
CE-conformityEMC directive: 2004/108/EC, EN 61326-2-3
SealWetted parts: EPDM
Enclosure rating

IP65 

IP67 

Protection class III
Performance
Non-linearity≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
Accuracy≤ ± 1 % of the span
Setting accuracy of switching outputs≤ ± 0.5 % of span
Response time3 ms
Long-term drift/one-year stability ≤ ± 0.2 % of the span according to IEC 61298-2
Temperature coefficient in rated temperature rangeTypical TC of the zero point: in temperature range 0 °C ... 20 °C: 0.7% of the range / 10 K; in temperature range 20 °C ... 80 °C: 0.2% of span / 10 K.
Typical TC of span: in temperature range 0 °C ... 80 °C: 0.1% of span / 10 K 
Rated temperature range0 °C ... +80 °C
Ambient data
Ambient temperature–20 °C ... +80 °C
Storage temperature–20 °C ... +80 °C
Relative humidity45 % ... 75 %
Shock load50 g according to IEC 60068-2-27 (mechanical shock)
Vibration load10 g according to IEC 60068-2-6 (vibration under resonance)
Classifications
eCl@ss 5.027200620
eCl@ss 5.1.427200620
eCl@ss 6.027200620
eCl@ss 6.227200620
eCl@ss 7.027200620
eCl@ss 8.027200620
eCl@ss 8.127200620
eCl@ss 9.027200620
eCl@ss 10.027200620
eCl@ss 11.027200620
eCl@ss 12.027200620
ETIM 5.0EC000243
ETIM 6.0EC000243
ETIM 7.0EC000243
ETIM 8.0EC000243
UNSPSC 16.090141112409
Specifiche
Unit weight0.935 Kilograms
Net unit weight0.935 Kilograms
Unit volume7779.75 Cubic Centimetres (cm³)
Measurements20.500*16.500*23.000
Country of originGermany