Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

SICK 6063622
SICKNon disponibile

OD5000-C30W05

Laser distance sensors: OD5000
Cod. Articolo: 6063622
Cod. Fornitore: 6063622
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Mechanics/electronics
Supply voltage VsDC 12 V ... 24 V, ± 10%, including residual ripple
Power consumption180 mA, at 24 V
Warm-up time< 10 min
Housing materialMetal (Aluminum die cast)
Window materialPlastic (PMMA)
Connection typeCable with male connector, M12, 8-pin, A-coded, 50 cm
IndicationStatus LEDs
Weight280 g
Dimensions (W x H x D)25.9 mm x 71.5 mm x 53.2 mm
Enclosure ratingIP67
Protection classIII (EN 50178)
Safety-related parameters
MTTFD61 years
DCavg0%
Performance
Measurement range min ... max:25 mm ... 35 mm 
TargetNatural objects
Repeatability0.05 µm  
Linearity

Diffuse ± 1.5 µm, Near side

Diffuse ± 1.5 µm, Far side

Specular ± 4 µm, Near side

Specular ± 4 µm, Far side

Response time≥ 12.5 µs  
Measuring frequency≤ 80 kHz 
Output time≥ 0.0125 ms
Light sourceLaser, red
visible red light
Laser class1 (IEC 60825-1:2014, EN 60825-1:2014) 
Typ. light spot size (distance)30 µm x 1,000 µm
Special taskThickness measurement of transparent material
Thickness measurement of transparent material0.18 mm ... 0.6 mm
Interfaces
Ethernet✔ , TCP/IP, UDP
Digital inputIn1
Can be used as laser off, external teach-in, or deactivated
Digital output
Number1 ... 3 
TypePNP/NPN, selectable
Analog output
Number1
TypeCurrent output
FunctionOptional over evaluation unit AOD1
Current4 mA ... 20 mA, ≤ 300 Ω
Ambient data
Ambient temperature, operation–10 °C ... +50 °C, Operating temperature at VS = 24 V
Ambient temperature, storage–20 °C ... +60 °C
Relative air humidity (non-condensing)35 % ... 85 %
Temperature drift

± 0.01 % FS/K at –10 °C ... +40 °C (FS = Full Scale = sensor measuring range)

± 0.03 % FS/K at +40 °C ... +50 °C (FS = Full Scale = sensor measuring range)

Typ. Ambient light immunity

Artificial light: ≤ 3,000 lx 

Sunlight: ≤ 10,000 lx

Vibration resistanceEN 60068-2-6, EN 60068-2-64
Shock resistanceEN 60068-2-27
Classifications
eCl@ss 5.027270801
eCl@ss 5.1.427270801
eCl@ss 6.027270801
eCl@ss 6.227270801
eCl@ss 7.027270801
eCl@ss 8.027270801
eCl@ss 8.127270801
eCl@ss 9.027270801
eCl@ss 10.027270801
eCl@ss 11.027270801
eCl@ss 12.027270916
ETIM 5.0EC001825
ETIM 6.0EC001825
ETIM 7.0EC001825
ETIM 8.0EC001825
UNSPSC 16.090141111613
Specifiche
Unit weight0.443 Kilograms
Net unit weight0.443 Kilograms
Unit volume1588.75 Cubic Centimetres (cm³)
Measurements12.500*8.200*15.500
Country of originJapan