MediumLiquid, gaseous
Pressure typeGauge pressure
Pressure unitbar
Measuring range0 bar ... 10 bar
Process temperature0 °C ... +80 °C
Maximum ohmic load RA

4 mA ... 20 mA, 2-wire (RA ≤ (L+ - 8 V) / 0.02 A [Ohm])

0 V ... 10 V, 3-wire (RA > 10 kOhm)

0 V ... 5 V, 3-wire (RA > 5 kOhm)

Output signal4 mA ... 20 mA, 2-wire
SpecialtyWithout
Mechanics/electronics
Process connectionG ½ A according to DIN 3852-E
Wetted parts

Pressure Connection: stainless steel 316L

Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH)

Internal transmission fluidSilicone oil (only with pressure ranges < 0 bar ... 10 bar and ≤ 0 bar abs ... 25 bar abs)
Pressure port0.3 mm pressure port
Housing materialStainless steel
Connection typeM12 round connector x 1, 4-pin
Supply voltage8 V DC ... 30 V DC 
Power consumption

Signal current (max. 25 mA) for current output

Max. 8 mA for voltage output signal

Electrical safety

Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA

Short-circuit protection: QA towards M

Reverse polarity protection: L+ to M

Protection class: III

Isolation voltage500 V DC
CE-conformity

Pressure equipment directive: 2014/68/EU

EMC directive: 2014/30/EU, EN 61 326-2-3

Weight sensorApprox. 80 g
SealNBR
Enclosure ratingIP67 
Protection class III
Reference conditionsReference conditions: According to IEC 61298-1
MTTF815 years
Performance
Non-linearity≤ ± 0.5 %, of the span
Accuracy≤ ± 1 % of the span
Adjustment accuracy of zero signal≤ 0.5 % of span typ., ≤ 0.8 % of span max. (with non-linerarity 0.5 %)
Hysteresis≤ 0.16 % of the span
Non-repeatability≤ 0.1 % of the span
Response time< 4 ms
Signal noise≤ 0.3 % of the span
Long-term drift/one-year stability ≤ 0.1 % of span to IEC 61298-2
Rated temperature range0 °C ... +80 °C
Service lifeMinimum 100 Mio. load cycles
Ambient data
Ambient temperature0 °C ... +80 °C
Storage temperature–40 °C ... +70 °C
Relative humidity45 % ... 75 %
Shock load500 g according to IEC 60068-2-27 (mechanical shock)
Vibration load

10 g according to IEC 60068-2-6 (vibration under resonance)

20 g optional

Classifications
eCl@ss 5.027200614
eCl@ss 5.1.427200614
eCl@ss 6.027200614
eCl@ss 6.227200614
eCl@ss 7.027200614
eCl@ss 8.027200614
eCl@ss 8.127200614
eCl@ss 9.027200614
eCl@ss 10.027200614
eCl@ss 11.027200614
eCl@ss 12.027200614
ETIM 5.0EC011478
ETIM 6.0EC011478
ETIM 7.0EC011478
ETIM 8.0EC011478
UNSPSC 16.090141112410
Specifiche
Unit weight0.099 Kilograms
Net unit weight0.099 Kilograms
Measurements.000*.000*.000
Country of originGermany