Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

SICK 6072424
SICKNon disponibile

PET-1RP1K0N10SRMR

Pressure sensors: PET
Cod. Articolo: 6072424
Cod. Fornitore: 6072424
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
Pressure typeGauge pressure
Measuring range0 psi ... 1,000 psi
Process temperature–30 °C ... +100 °C
Output signal0.5 V ... 4.5 V, ratiometric, 3-conductor
Pieces per package50 pieces
Mechanics/electronics
Process connection¼'' NPT
SealWithout seal
Wetted partsStainless steel, stainless steel 13-8 PH
Pressure port3.5 mm Standard
Housing materialStainless steel 316L, PBT GF30
Connection typeM12 round connector x 1, 4-pin
Enclosure ratingIP67, for round connector (IEC 60529) 
Supply voltage5 V DC, ± 10 % 
Maximum ohmic load RA> 4.5 kΩ with ratiometric output signal
Maximum power consumption5 mA
Initialization time15 ms
Protection classIII
Isolation voltage750 V DC
Overvoltage protection36 V DC
Short-circuit protectionOutput QA towards M
Reverse polarity protectionL+ towards M
CE-conformity2004/108/EC, EN 61326-1 emission (group 1, class B) and interference immunity (industrial application) and pressure equipment directive 97/23/EC
RoHS certificate
Service lifeMinimum 10 Mio. load cycles
MTTF> 100 years
Performance
Non-linearity≤ ± 0.5 % of span (best fit straight line, BFSL)
Accuracy≤ ± 1.2 % of span (at room temperature)
Response time< 2 ms
Measurement deviation of zero signal≤ ± 0.5 % of the span
Temperature error≤ ± 1.5 % of the span
Long-term drift/one-year stability ≤ ± 0.3 % of span (per year)
Rated temperature range0 °C ... +80 °C
Reference conditionsAccording to IEC 61298-1
Ambient data
Ambient temperature, operation–30 °C ... +100 °C
Storage temperature–30 °C ... +100 °C
Shock load40 g (6 ms) according to IEC 60068-2-27 (mechanical shock)
Vibration load20 g (20 Hz ... 2000 Hz, 120 min) according to IEC 60068-2-6 (vibration at resonance)
Classifications
eCl@ss 5.027200614
eCl@ss 5.1.427200614
eCl@ss 6.027200614
eCl@ss 6.227200614
eCl@ss 7.027200614
eCl@ss 8.027200614
eCl@ss 8.127200614
eCl@ss 9.027200614
eCl@ss 10.027200614
eCl@ss 11.027200614
eCl@ss 12.027200614
ETIM 5.0EC011478
ETIM 6.0EC011478
ETIM 7.0EC011478
ETIM 8.0EC011478
UNSPSC 16.090141112410
Specifiche
Unit weight56.000 Grams
Net unit weight56 Grams
Unit volume49.5 Cubic Centimetres (cm³)
Measurements3.000*3.000*5.500
Country of originPoland