SICK 6074193
SICKNon disponibile

PBS2-CB6X0SF2FSDLMA0Z

Pressure sensors: PBS plus
Cod. Articolo: 6074193
Cod. Fornitore: 6074193
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
MediumLiquid, gaseous
Pressure typeCompound pressure
Pressure unitbar
Measuring range

–1 bar ... 5 bar

–14.5 psi ... 73 psi

Process temperature–20 °C ... +85 °C
Maximum ohmic load RA

4 mA ... 20 mA (RA ≤ 0.5 kOhm)

0 V ... 10 V, 3-wire (RA > 10 kOhm)

Zero point adjustmentMax. + 3 % of span
Output signalIO-Link/PNP/NPN + PNP/NPN
Rotatable housing

Display against housing with electrical connection: 330 °

Housing against process connection: 320 °

Display

14-Segment LED, red, 4-digit, character height 9 mm, can be rotated electronically by 180°

Update: 1,000, 500, 200, 100 ms (adjustable)

Mechanics/electronics
Process connectionG ½ B flush mounted
Wetted parts

Pressure connection: stainless steel 316L

Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH)

Internal transmission fluidSilicone oil (only with pressure ranges < 0 bar ... 10 bar and ≤ 0 bar abs ... 25 bar abs)
Pressure portFront-flush membrane
Housing materialLower body: stainless steel 304, Plastic head: PC + ABS, Buttons: TPE-E, Display window: PC
Connection typeM12 round connector x 1, 4-pin
Supply voltage15 V DC ... 35 V DC
Power consumption

45 mA (for configurations without analog output signal)

70 mA (for configurations with analog output signal)

Total current consumptionMax. 600 mA (including switching current)
Electrical safety

Protection class: III

Overvoltage protection: 40 V DC

Short-circuit protection: QA, Q1, Q2 towards M

Reverse polarity protection: L+ to M

Isolation voltage500 V DC
CE-conformityEMC Directive: 2014/30 / EU (EN 61326-1:2013; EN 61326-2-3:2013), Pressure equipment directive: 2014/68 / EU, Hazardous materials (RoHS): 2011/65 / EU (EN 50581:2012)
Weight sensorApprox. 220 g
SealNBR seal installed, FPM/FKM seal included
Enclosure ratingIP67 
Protection class III
MTTF104 years
Performance
Non-linearity≤ ± 0.25 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
Accuracy≤ ± 0.5 % of the span
Setting accuracy of switching outputs≤ ± 0.5 % of span
Response time≤ 5 ms
Long-term drift/one-year stability

≤ ± 0.1 % of the span according to IEC 61298-2

≤ 0.2 % of the span According to IEC 61298-2 for measuring range ≤ 0.6 bar or flush-mounted membrane (0 psi ... 10 psi)

Temperature coefficient in rated temperature range

Average TC of the zero point: ≤± 0.16% of the span / 10 K

Average TC of the span ≤± 0.16% of the span / 10 K

Rated temperature range0 °C ... +80 °C
Service lifeMinimum 100 Mio. load cycles
Ambient data
Ambient temperature–20 °C ... +80 °C
Storage temperature–20 °C ... +70 °C
Relative humidity≤ 75 %
Shock load50 g, 6 ms according to IEC 60068-2-27 (mechanical shock)
Vibration load20 g, 10 Hz ... 2,000 Hz (IEC 60068-2-6, at resonance)
Classifications
eCl@ss 5.027200620
eCl@ss 5.1.427200620
eCl@ss 6.027200620
eCl@ss 6.227200620
eCl@ss 7.027200620
eCl@ss 8.027200620
eCl@ss 8.127200620
eCl@ss 9.027200620
eCl@ss 10.027200620
eCl@ss 11.027200620
eCl@ss 12.027200620
ETIM 5.0EC000243
ETIM 6.0EC000243
ETIM 7.0EC000243
ETIM 8.0EC000243
UNSPSC 16.090141112409
Specifiche
Unit weight0.322 Kilograms
Net unit weight0.322 Kilograms
Unit volume792.88 Cubic Centimetres (cm³)
Measurements8.800*5.300*17.000
Country of originGermany