SICK 6081910
SICKNon disponibile

LFR-ACFFHIMHAKX

Level sensors: LFR SicWave
Cod. Articolo: 6081910
Cod. Fornitore: 6081910
SICK


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
Features
MediumFluids
MeasurementContinuous
Probe typeFlange with encapsulated antenna system
Frequency bandW-band (within 75 … 85 GHz)
Measuring rangeUp to 30 m (98.43 ft)
Angle of dispersion3° 
Process pressureIn combination with process temperature –196 °C ... +200 °C, –1 bar ... 25 bar (-100 kPa ... 2,500 kPa / –14.5 psig ... 362.6 psig) are possible: –1 bar ... 16 bar
(-100 kPa ... 1,600 kPa / –14.5 psig ... 232 psig)
Process temperature–40 °C ... +130 °C
ATEX approvalATEX II 1G, 1/2G, 2G Ex ia IIC T6
Type examinationKIWA 20ATEX0039 X
RoHS certificate
HART
IndicationInstalled
Control element

Bluetooth

Magnet pin operation

Performance
Accuracy of sensor element≤ 1 mm 
Non-repeatability≤ 1 mm
Digital measurement resolution< 1 mm
Analog measurement resolution0.3 µA
Digital output temperature drift≤ 3 mm / 10 K, max. 10 mm
Current output temperature drift≤ 0.03% / 10 K relating to the 16 mA span or ≤ 0.3%
Deviation on current output due to digital-analog conversion< 15 µA
Measurement cycle timeApprox. 700 ms
Step response time≤ 3 s 
MTBF3,37*10^6 h
Display
Electronics
Supply voltage12 V DC ... 35 V DC, 18 V DC ... 35 V DC with illumination switched on 
Protection classIII (IEC 61010-1)
Connection typeM20 x 1.5 / cable gland PA black (ø 5 mm - 9 mm)
Output signal4 mA ... 20 mA / HART 
Contamination rating4
Enclosure ratingIP66 / IP68
EMCEN 61326-1
Start-up current< 3.6 mA
Overvoltage categoryIII (IEC 61010-1)
Short-circuit protection
Mechanics
Process connectionFlange DN 80 PN 40 form C, DIN 2501 / 316L
Housing materialAluminum
Housing designSingle-chamber housing
Sealing materialPTFE
Antenna materialPTFE
Second line of defenseNot integrated
Ambient data
Ambient operating temperature–40 °C ... +80 °C
Ambient temperature, storage–40 °C ... +80 °C
Classifications
ECLASS 5.027200505
ECLASS 5.1.427200505
ECLASS 6.027200505
ECLASS 6.227200505
ECLASS 7.027200505
ECLASS 8.027200505
ECLASS 8.127200505
ECLASS 9.027200505
ECLASS 10.027270807
ECLASS 11.027270807
ECLASS 12.027274501
ETIM 5.0EC001447
ETIM 6.0EC001447
ETIM 7.0EC001447
ETIM 8.0EC001447
UNSPSC 16.090141111950
Specifiche
Unit weight0.099 Kilograms
Net unit weight0.099 Kilograms
Measurements.000*.000*.000
Country of originGermany