Basic data | Series: 8 Type of scanning system: Against object |
Optical data | Light source: Laser, Red Laser class: 2, IEC/EN 60825-1:2007 Light spot size [at sensor distance]: 2 mm x 6 mm |
Measurement data | Measurement range: 20 ... 500 mm Resolution: 0.1 ... 0.5 mm Accuracy, short range: 2 % Accuracy, distant range: 4 % Reference value, accuracy: Measurement distance Repeatability, short range: 1 % Repeatability, distant range: 3 % Reference value repeatability: Measurement distance Measurement time: 2 ... 7 ms Referencing: No Black/white behavior: 1.5 % Optical distance measurement principle: Triangulation |
Electrical data | Performance data Supply voltage UB: 10 ... 30 V, DC Outputs Number of digital switching outputs: 2 Piece(s) Switching output 1: Array Switching output 2: Array |
Connection | Connection 1 Type of connection: Connector, Turning, 90° Thread size: M12 Material: Metal No. of pins: 5 -pin |
Mechanical data | Dimension (W x H x L): 15 mm x 48 mm x 38 mm Housing material: Metal Metal housing: Diecast zinc Lens cover material: Glass Net weight: 70 g |
Operation and display | Type of configuration: Switch Operational controls: Rotary switch |
Environmental data | Ambient temperature, operation: -40 ... 50 °C Ambient temperature, storage: -40 ... 70 °C |