Industrial Automation
DDLS 200/300.2-10-H-M12
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Basic data | Series: DDLS 200 |
Special version | Special version: Heating Not influenced by reflective surfaces Operation of parallel light axes |
Optical data | Working range: 200 ... 300,000 mm Light source: LED, Infrared Transmission frequency: F2 Usable opening angle transmitter: 1 ° |
Electrical data | Performance data Supply voltage UB: 18 ... 30 V, DC Inputs Number of digital switching inputs: 1 Piece(s) Outputs Number of digital switching outputs: 1 Piece(s) |
Interface | Type: PROFIBUS DP, RS 485 PROFIBUS DP Transmission speed: 0.0096 ... 1.5 Mbit/s |
Connection | Number of connections: 3 Piece(s) Connection 1 Type of connection: Connector Designation on device: BUS IN Thread size: M12 Type: Male No. of pins: 5 -pin Encoding: B-coded Connection 2 Type of connection: Connector Designation on device: Bus OUT Thread size: M12 Type: Female No. of pins: 5 -pin Encoding: B-coded Connection 3 Type of connection: Connector Designation on device: PWR Thread size: M12 Type: Male No. of pins: 5 -pin Encoding: A-coded |
Mechanical data | Dimension (W x H x L): 89.25 mm x 196.5 mm x 111.8 mm Housing material: Metal Net weight: 1,245 g |
Operation and display | Type of display: Bar graph LED |
Environmental data | Ambient temperature, operation: -30 ... 50 °C Ambient temperature, storage: -30 ... 70 °C |
Certifications | Degree of protection: IP 65 Certifications: c UL US Test procedure for EMC in accordance with standard: EN 61000-6-2:2005 EN 61000-6-4:2001 Test procedure for noise in accordance with standard: EN 60068-2-64 Test procedure for oscillation in accordance with standard: EN 60068-2-6 Test procedure for shock in accordance with standard: EN 60068-2-27 EN 60068-2-29 |