Industrial Automation
Basic data | Series: 96 Type of scanning system: Against object |
Special version | Special version: Ex-protected |
Optical data | Light source: Laser, Red Laser class: 2, IEC/EN 60825-1:2014 Light spot size [at sensor distance]: 2 mm x 6 mm [2,000 mm] |
Measurement data | Measurement range: 150 ... 2,000 mm Resolution: 1.0 ... 3.0 mm Accuracy: 1.5 % Reference value, accuracy: Measurement distance Repeatability: 0.5 % Reference value repeatability: Measurement distance Measurement time: 1 ... 5 ms Referencing: No Black/white behavior: 1 % Optical distance measurement principle: Triangulation |
Electrical data | Performance data Supply voltage UB: 18 ... 30 V, DC Inputs Number of digital switching inputs: 1 Piece(s) Outputs Number of analog outputs: 1 Piece(s) Number of digital switching outputs: 1 Piece(s) Analog output 1: Array Switching output 1: Array |
Connection | Connection 1 Type of connection: Cable Cable length: 15,000 mm Number of conductors: 5 -wire |
Mechanical data | Dimension (W x H x L): 150 mm x 150 mm x 124 mm Housing material: Metal Metal housing: Diecast zinc Lens cover material: Glass Net weight: 3,941 g |
Operation and display | Type of configuration: Software Operational controls: Membrane keyboard PC software |
Environmental data | Ambient temperature, operation: -20 ... 50 °C Ambient temperature, storage: -30 ... 70 °C |
Ex specification | Ex device category: 2D 2G |
Ex-Spezifikation | Ex-Zone: 1 21 |
Certifications | Degree of protection: IP 67 IP 69K Protection class: II Standards applied: IEC 60947-5-2 |