Industrial Automation
Basic data | Series: 244 Typ. operating range limit Sn: 20 mm Operating range Sa: 0 ... 16.2 mm |
Special version | Special version: Antivalent |
Electrical data | Protective circuit: Inductive protection Polarity reversal protection Short circuit protected Performance data Supply voltage UB: 10 ... 30 V, DC Residual ripple: 0 ... 20 %, From UB Open-circuit current: 0 ... 20 mA Repeatability, max. (in % of Sr): 10 %, For UB = 20 … 30 V DC, ambient temperature Ta = 23 °C ± 5 °C Switching hysteresis: 5 % Outputs Number of digital switching outputs: 2 Piece(s) Switching outputs: Array Switching output 1: Array Switching output 2: Array |
Time behavior | Switching frequency: 440 Hz Readiness delay: 80 ms |
Connection | Number of connections: 1 Piece(s) Connection 1 Function: Signal OUT Voltage supply Type of connection: Terminal No. of pins: 4 -pin |
Mechanical data | Design: Cubic Dimension (W x H x L): 40 mm x 40 mm x 118 mm Type of installation: Embedded Housing material: Plastic Plastic housing: PA 66 Sensing face material: Plastic, Polyamide (PA 66) Net weight: 225 g Housing color: Black Type of fastening: Through-hole mounting Standard measuring plate: 60 x 60 mm², Fe360 |
Operation and display | Type of display: LED Number of LEDs: 4 Piece(s) |
Environmental data | Ambient temperature, operation: -25 ... 85 °C Ambient temperature, storage: -25 ... 85 °C |
Certifications | Degree of protection: IP 68 IP 69K Protection class: II Certifications: c UL US Test procedure for EMC in accordance with standard: IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 Standards applied: IEC 60947-5-2 |
Correction factors | Aluminum: 0.33 Stainless steel: 0.74 Copper: 0.31 Brass: 0.38 Fe360 steel: 1 |