Industrial Automation
Basic data | Series: 3C Operating principle: Diffuse reflection principle with background suppression Application: Detection of highly transparent bottles Detection of objects with openings Detection of transparent films |
Special version | Special version: Extra long light spot (XL) |
Optical data | Black-white error: < 10% up to 60 mm Operating range: Guaranteed operating range Operating range, white 90%: 0.005 ... 0.05 m Operating range, gray 18%: 0.005 ... 0.045 m Operating range, black 6%: 0.005 ... 0.04 m Operating range limit: Typical operating range Operating range limit, white 90%: 0.005 ... 0.1 m Operating range limit, gray 18%: 0.005 ... 0.09 m Operating range limit, black 6%: 0.005 ... 0.08 m Adjustment range: 20 ... 100 mm Beam path: Divergent Light source: LED, Red Wavelength: 633 nm LED group: Exempt group (in acc. with EN 62471) Light spot size [at sensor distance]: 3 mm x 40 mm [50 mm] Type of light spot geometry: Rectangular |
Electrical data | Protective circuit: Polarity reversal protection Short circuit protected Performance data Supply voltage UB: 10 ... 30 V, DC, Incl. residual ripple Residual ripple: 0 ... 15 %, From UB Open-circuit current: 0 ... 15 mA Outputs Number of digital switching outputs: 2 Piece(s) Switching output 1: Array Switching output 2: Array |
Time behavior | Switching frequency: 1,000 Hz Response time: 0.5 ms Readiness delay: 300 ms |
Connection | Connection 1 Function: Signal OUT Voltage supply Type of connection: Cable Cable length: 2,000 mm Sheathing material: PUR Cable color: Black Number of conductors: 4 -wire Wire cross section: 0.2 mm² |
Mechanical data | Dimension (W x H x L): 11.4 mm x 34.2 mm x 18.3 mm Housing material: Plastic Plastic housing: PC-ABS Lens cover material: Plastic / PMMA Net weight: 50 g Housing color: Red Type of fastening: Through-hole mounting Via optional mounting device Compatibility of materials: ECOLAB |
Operation and display | Type of display: LED Operational controls: Multiturn potentiometer Function of the operational control: Range adjustment |
Environmental data | Ambient temperature, operation: -40 ... 60 °C Ambient temperature, storage: -40 ... 70 °C |
Certifications | Degree of protection: IP 67 IP 69K Protection class: III Certifications: c UL US Standards applied: IEC 60947-5-2 |
Description other products