LEUZE 50141683
LEUZE 50141683
LEUZE 50141683
LEUZENot available

HT15/PX-200-M12

Diffuse sensor with background suppression
Product Code: 50141683
Partner cod.: 50141683
LEUZE


Diminuisci la quantità
Aumenta la quantità
Technical Specs
Technical Specs
Basic dataSeries: 15
Operating principle: Diffuse reflection principle with background suppression
Optical dataBlack-white error: < 15% up to 350 mm
Operating range: Guaranteed operating range
Operating range, white 90%: 0.012 ... 1 m
Operating range, gray 18%: 0.012 ... 0.7 m
Operating range, black 6%: 0.012 ... 0.5 m
Operating range limit: 0.012 ... 1 m
Adjustment range: 50 ... 1,000 mm
Light source: LED, Red
Wavelength: 640 nm
LED group: Exempt group (in acc. with EN 62471)
Electrical dataProtective circuit: Polarity reversal protection
Short circuit protected
Performance data
Supply voltage UB: 10 ... 30 V, DC, Incl. residual ripple
Residual ripple: 0 ... 15 %, From UB
Open-circuit current: 0 ... 20 mA
Outputs
Number of digital switching outputs: 1 Piece(s)
Switching output 1: Array
Time behaviorSwitching frequency: 500 Hz
Response time: 1 ms
Readiness delay: 300 ms
ConnectionConnection 1
Function: Signal OUT
Voltage supply
Type of connection: Cable with connector
Cable length: 200 mm
Sheathing material: PUR
Cable color: Black
Wire cross section: 0.14 mm²
Thread size: M12
Type: Male
Material: Plastic
No. of pins: 4 -pin
Encoding: A-coded
Mechanical dataDimension (W x H x L): 15 mm x 42.7 mm x 30 mm
Housing material: Plastic
Plastic housing: ABS
Lens cover material: Plastic
Net weight: 22 g
Housing color: Black
Type of fastening: Through-hole mounting
Via optional mounting device
Operation and displayType of display: LED
Operational controls: Multiturn potentiometer
Function of the operational control: Range adjustment
Environmental dataAmbient temperature, operation: -40 ... 60 °C
Ambient temperature, storage: -40 ... 70 °C
CertificationsDegree of protection: IP 67
Protection class: III
Certifications: c UL US
Standards applied: IEC 60947-5-2