LEUZE 50145947
LEUZE 50145947
LEUZE 50145947
LEUZENot available

ISS 212MM/2NO-4E0

Inductive switch
Product Code: 50145947
Partner cod.: 50145947
LEUZE


Diminuisci la quantità
Aumenta la quantità
Technical Specs
Technical Specs
Basic dataSeries: 212
Typ. operating range limit Sn: 4 mm
Operating range Sa: 0 ... 3.2 mm
Electrical dataProtective circuit: Inductive protection
Polarity reversal protection
Short circuit protected
Performance data
Supply voltage UB: 10 ... 30 V, DC
Residual ripple: 0 ... 20 %, From UB
Open-circuit current: 0 ... 10 mA
Temperature drift, max. (in % of Sr): 10 %, Over the entire operating temperature range
Repeatability, max. (in % of Sr): 5 %, For UB = 20 … 30 V DC, ambient temperature Ta = 23 °C ± 5 °C
Switching hysteresis: 20 %
Outputs
Number of digital switching outputs: 1 Piece(s)
Switching outputs: Array
Switching output 1: Array
Time behaviorSwitching frequency: 2,500 Hz
Readiness delay: 60 ms
ConnectionNumber of connections: 1 Piece(s)
Connection 1
Function: Signal OUT
Voltage supply
Type of connection: Cable
Cable length: 2,000 mm
Sheathing material: PVC
Cable color: Gray
Number of conductors: 3 -wire
Wire cross section: 0.34 mm²
Mechanical dataDesign: Cylindrical
Thread size: M12 x 1 mm
Dimension (∅ x L): 12 mm x 35 mm
Type of installation: Embedded
Housing material: Metal
Metal housing: Nickel-plated brass
Sensing face material: Plastic, Polybutylene (PBT)
Net weight: 91 g
Housing color: Red, RAL 3000
Silver
Type of fastening: Mounting thread
Standard measuring plate: 12 x 12 mm², Fe360
Operation and displayType of display: LED
Number of LEDs: 1 Piece(s)
Environmental dataAmbient temperature, operation: -25 ... 70 °C
Ambient temperature, storage: -25 ... 70 °C
CertificationsDegree of protection: IP 67
Protection class: II
Certifications: c UL US
Test procedure for EMC in accordance with standard: IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
Standards applied: IEC 60947-5-2
Correction factorsAluminum: 0.44
Stainless steel: 0.8
Copper: 0.4
Brass: 0.54
Fe360 steel: 1