Industrial Automation
S200-M4C1-M12
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Basic data | Series: S200 |
Functions | Functions: Integration in control circuits up to category4 in accordance with EN ISO 13849-1 Mechanically coded interlock device of type 2 acc. to EN ISO 14119 |
Characteristic parameters | SIL: 3, IEC 61508 SILCL: 3, IEC/EN 62061 Performance Level (PL): Up to and including e, EN ISO 13849-1 Mission time: 20 years, EN ISO 13849-1 B10d: 2,000,000 number of cycles |
Electrical data | Usage category at DC 13: Ue 24 V, Ie 2 A, EN 60947-5-1 Usage category at AC 15: Ue 24 V, Ie 2 A, EN 60947-5-1 Contact allocation: 2NC + 1NO Contact opening: Force-fit Short circuit protected: 500 V, 2 A, type gG, IEC 60269-1 Contact protection: Earthing Performance data Rated insulation voltage: 30 V AC, 36 V DC Conventional thermal current, max.: 2 A |
Connection | Number of connections: 1 Piece(s) Connection 1 Function: Contact connection Type of connection: Connector Thread size: M12 Material: Metal No. of pins: 8 -pin |
Mechanical data | Design: Cubic Dimension (W x H x L): 40 mm x 38 mm x 109.5 mm Housing material: Metal Metal housing: ZAMAK Electrical contact material: Silver alloy Net weight: 310 g Housing color: Gray Red Type of fastening: Through-hole mounting Switch type: Interlock device without guard interlocking, ISO 14119 Switching principle: Slow-action contact Approach actuation directions: 1 x top 4 x side (90°) Approach speed: 0 ... 0.5 m/s Mechanical life time: 1,000,000 actuation cycles, IEC 6047-5-1 Actuation frequency, max.: 3,600 per hour, IEC 6047-5-1 External actuator: AC-AHxx, series, straight, angled, resilient, alignable Extraction force, unlocked actuator: 10 N Actuating path with forced separation: 8.8 mm Recoil tolerance: 4.5 mm |
Environmental data | Ambient temperature, operation: -25 ... 80 °C Degree of contamination: 3, EN 60947-1 |
Certifications | Degree of protection: IP 67 Certifications: IMQ c UL US |