Industrial Automation
Basic data | Series: MC330 |
Functions | Functions: Integration in control circuits up to category4 in accordance with EN ISO 13849-1 Safety system in combination with an evaluation unit such as the MSI-MC310 safety relay or the MSI 400 safety controller. |
Characteristic parameters | Mission time: 20 years, EN ISO 13849-1 Category: Up to 4, depending on evaluation, 1 sensor connected, EN ISO 13849-1 B10d: 20,000,000 number of cycles |
Electrical data | Protective circuit: Current limitation Short circuit protected,Via e.g. MSI-MC310, MSI 400 Contact allocation: 1NC + 1NO Contact type: Reed contacts (magnetically sensitive) Requirement on the voltage supply when used acc. to cULus (UL 508): Class 2 Circuits Outputs Max. switching voltage: 27 V AC/DC Switching current, max.: 500 mA |
Time behavior | Response time: 3 ms |
Connection | Number of connections: 1 Piece(s) Connection 1 Function: Contact connection Type of connection: Cable with wire-end sleeves Cable length: 10,000 mm Sheathing material: PVC Cable color: Gray Number of conductors: 4 -wire |
Mechanical data | Design: Cylindrical Thread size: M30 x 3.5 mm Dimension: 36 mm Housing material: Plastic Plastic housing: Glass fiber reinforced (PPS), self-extinguishing Net weight: 561 g Housing color: Red Type of fastening: Mounting thread Installation position: Arbitrary, provided housing markings are aligned Switch type: Type 4 interlock device, contactless actuation, EN ISO 14119 Approach actuation directions: 3-dimensional Mechanical life time: 10,000,000 actuation cycles External actuator: Magnetically coded Cut-out point (OFF), min.: 12 mm Assured cut-out distance (Sar), min.: 14 mm Assured cut-in distance (Sao), max.: 6 mm Switching tolerance (without ferromagnetic materials in immediate vicinity): -1 ... 1 mm Distance to other magnetic sensors, min.: 50 mm Approach speed, min.: 0.05 m/s |
Environmental data | Ambient temperature, operation: -20 ... 70 °C Degree of contamination: 3, EN 60947-1 |
Certifications | Degree of protection: IP 67 Certifications: TÜV Süd (with suitable safety relay) c UL US Test procedure for EMC in accordance with standard: EN 60947-5-3 EN 61000-6-2 EN 61000-6-3 Test procedure for oscillation in accordance with standard: EN 60947-5-3 Test procedure for shock in accordance with standard: EN 60947-5-3 |