Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

LEUZE 66563700
LEUZE 66563700
LEUZE 66563700
LEUZE 66563700
LEUZENot available

MLD530-XR4

Multiple light beam safety device receiver
Product Code: 66563700
Partner cod.: 66563700
LEUZE


Diminuisci la quantità
Aumenta la quantità
Technical Specs
Technical Specs
Basic dataSeries: MLD 500
Device type: Receiver
FunctionsFunctions: Alternative connection for second muting signal
Configuration by means of wiring
Contactor monitoring (EDM), selectable
Muting-timeout extension
Muting enable function
Partial muting
Sequence controlled 2-sensor muting
Start/restart interlock (RES)
Timing controlled 2-sensor muting
Reflective element for laser alignment aid: No
Integrated muting indicator: No
Integrated status indicator: No
Characteristic parametersType: 4, IEC/EN 61496
SIL: 3, IEC 61508
SILCL: 3, IEC/EN 62061
Performance Level (PL): e, EN ISO 13849-1
MTTFd: 204 years, EN ISO 13849-1
PFHD: 6.6E-09 per hour
Mission time: 20 years, EN ISO 13849-1
Category: 4, EN ISO 13849
Optical dataNumber of beams: 4 Piece(s)
Beam spacing: 300 mm
Electrical dataSelection of operating mode: Connection 1, pin 2: +24 V for operating mode 1, 2, 4
Connection 1, pin 2: 0 V for operating mode 3, 5, 6
Connection 1, pin 7: +24 V for operating mode 3, 5, 6
Connection 1, pin 7: 0 V for operating mode 1, 2, 4
Protective circuit: Overvoltage protection
Short circuit protected
Performance data
Supply voltage UB: 24 V, DC, -20 ... 20 %
Current consumption, max.: 150 mA, Without external load
Fuse: External with max. 3 A
Inputs
Number of digital switching inputs: 4 Piece(s)
Switching inputs: Array
Outputs
Number of safety-related switching outputs (OSSDs): 2 Piece(s)
Number of digital switching outputs: 1 Piece(s)
Safety-related switching outputs: Array
Safety-related switching output 1: Array
Safety-related switching output 2: Array
Switching outputs: Array
Time behaviorResponse time: 50 ms
Restart delay time: 100 ms
ConnectionNumber of connections: 2 Piece(s)
Connection 1
Function: Machine interface
Type of connection: Connector
Thread size: M12
Material: Metal
No. of pins: 8 -pin
Connection 2
Function: Local interface
Type of connection: Connector
Thread size: M12
Material: Metal
No. of pins: 5 -pin
Cable properties
Permissible conductor cross section, typ.: 0.25 mm²
Length of connection cable, max.: 100 m
Permissible cable resistance to load, max.: 200 Ω
Mechanical dataDimension (W x H x L): 52 mm x 1,000 mm x 64.7 mm
Housing material: Metal
Metal housing: Aluminum
Lens cover material: Plastic / PMMA
Material of end caps: Diecast zinc
Net weight: 2,200 g
Housing color: Yellow, RAL 1021
Type of fastening: Groove mounting
Swivel mount
Operation and displayType of display: 7‑segment display
LED
Number of LEDs: 2 Piece(s)
Environmental dataAmbient temperature, operation: -30 ... 55 °C
Ambient temperature, storage: -40 ... 75 °C
Relative humidity (non-condensing): 0 ... 95 %
CertificationsDegree of protection: IP 67
Protection class: III
Certifications: TÜV Süd
c CSA US
c TÜV NRTL US
US patents: US 6,418,546 B
US 7,741,595 B