Industrial Automation
Basic data | Series: MLC 500 Device type: Receiver Cascading: Middle Guest Contains: 2x BT-NC sliding block Application: Hand protection |
Characteristic parameters | Type: 4, IEC/EN 61496 SIL: 3, IEC 61508 SILCL: 3, IEC/EN 62061 Performance Level (PL): e, EN ISO 13849-1 Mission time: 20 years, EN ISO 13849-1 Category: 4, EN ISO 13849 |
Protective field data | Resolution: 30 mm Protective field height: 600 mm |
Optical data | Number of beams: 24 Piece(s) |
Time behavior | Response time: 5 ms, plus response times of the Host/Guest devices |
Connection | Number of connections: 2 Piece(s) Connection 1 Function: Cascade, Host In Type of connection: Cable with connector Cable length: 330 mm Sheathing material: PUR Cable color: Black Wire cross section: 0.14 mm² Thread size: M12 Type: Male Material: Plastic No. of pins: 8 -pin Connection 2 Function: Cascade, Guest Out Type of connection: Cable with connector Cable length: 330 mm Sheathing material: PUR Thread size: M12 Type: Female Material: Plastic No. of pins: 8 -pin |
Mechanical data | Dimension (W x H x L): 29 mm x 614 mm x 53 mm Housing material: Metal Metal housing: Aluminum Lens cover material: Plastic / PMMA Material of end caps: Diecast zinc Net weight: 798 g Housing color: Yellow, RAL 1021 Type of fastening: Groove mounting Mounting brackets Swivel mount |
Environmental data | Ambient temperature, operation: 0 ... 55 °C Ambient temperature, storage: -30 ... 70 °C Relative humidity (non-condensing): 0 ... 95 % |
Certifications | Degree of protection: IP 65 Protection class: III Certifications: TÜV Süd c CSA US c TÜV NRTL US Vibration resistance: 50 m/s² Test procedure for oscillation in accordance with standard: IEC/EN 60068-2-6 Shock resistance: 100 m/s² Test procedure for shock in accordance with standard: IEC/EN 60068-2-6 US patents: US 6,418,546 B |