Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 0709123
PHOENIX CONTACTNot available

HDFK 50-VP - Panel feed-through terminal block

Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Cable lug connection, number of positions: 1, load current: 150 A, cross section: 16 mm2-50 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 18.8 mm
Product Code: 0709123
Partner cod.: 0709123
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Panel feed-through terminal block
Product family: HDFK 50-VP
Number of positions: 1
Pitch: 18.8 mm
Number of connections: 2
Number of rows: 1
Number of potentials: 1
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Electrical propertiesNominal current IN: 150 A
Nominal voltage UN: 690 V
Degree of pollution: 3
Rated voltage (III/3): 690 V
Rated surge voltage (III/3): 8 kV
Connection dataConnection technology
Connector system: HDFK 50
Nominal cross section: 50 mm²
Conductor connection exterior
Connection method: Screw connection with tension sleeve
Connection direction of the conductor to plug-in direction: 0°
Conductor cross section rigid: 16 mm² ... 50 mm²
Conductor cross section flexible: 16 mm² ... 50 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 10 mm² ... 50 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 10 mm² ... 50 mm²
2 conductors with same cross section, solid: 6 mm² ... 16 mm²
2 conductors with same cross section, flexible: 10 mm² ... 16 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve: 6 mm² ... 16 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 6 mm² ... 10 mm²
Internal cylindrical gage: B10
Stripping length: 24 mm
Tightening torque: 6 Nm ... 8 Nm
Conductor connection interior
Connection method: Cable lug connection
Connection direction of the conductor to plug-in direction: 0°
MountingPlate thickness: 1 mm ... 6 mm
Material specificationsMaterial data - contact
Note: WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Contact material: Cu alloy
Surface characteristics: tin-plated
Material data - housing
Color (Housing): gray (7042)
Insulating material: PA
Insulating material group: I
CTI according to IEC 60112: 600
Flammability rating according to UL 94: V0
Glow wire flammability index GWFI according to EN60695-2-12: 850
Glow wire ignition temperature GWIT according to EN60695-2-13: 775
Temperature for the ball pressure test according to EN60695-10-2: 125°C
NotesSafety note
Safety note: • Only electrically qualified personnel may install and operate the product.
To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering.
• Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data.
• The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection.
• To maintain the nominal voltage, align the cable lugs straight and centered, and cast the terminals on the inside.
 There is no electrical contact to the housing. Make sure that protective grounding is provided for green/yellow color variants and articles marked with PE.
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e840d33717330747ad0c7b5d4b264f71/-S204x204-FJPG
Pitch: 18.8 mm
Width [w]: 18.8 mm
External dimensions
Height [h1]: 54 mm
Length [l1]: 43 mm
Internal dimensions
Height [h2]: 37 mm
Length [l2]: 35 mm
Mechanical testsMechanical strength
Result: Test passed
Electrical testsAir clearances and creepage distances | 1. Insulation coordination
Application: Metal wall 4.5mm...6.0mm
Internal part molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 690 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 8 mm
Air clearances and creepage distances | 2. Insulation coordination
Application: Metal panel 2.0mm...4.5mm
Internal part molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 800 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 10 mm
Air clearances and creepage distances | 3. Insulation coordination
Application: Metal panel 1.0mm...2.0mm
Internal part molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 1000 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 12.5 mm
Air clearances and creepage distances | 4. Insulation coordination
Application: Plastic panel 1.0...6.0mm
Internal part molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 1000 V
Rated surge voltage (III/3): 8 kV
minimum clearance value - non-homogenous field (III/3): 8 mm
minimum creepage distance (III/3): 12.5 mm
Air clearances and creepage distances | 5. Insulation coordination
Application: Metal wall 1.0mm...6.0mm
Internal part not molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 250 V
Rated surge voltage (III/3): 4 kV
minimum clearance value - non-homogenous field (III/3): 3 mm
minimum creepage distance (III/3): 3.2 mm
Air clearances and creepage distances | 6. Insulation coordination
Application: Plastic panel 1.0...6.0mm
Internal part not molded
Specification: IEC 60947-7-1:2002-07
Insulating material group: I
Comparative tracking index (IEC 60112): CTI 600
Rated insulation voltage (III/3): 250 V
Rated surge voltage (III/3): 4 kV
minimum clearance value - non-homogenous field (III/3): 3 mm
minimum creepage distance (III/3): 3.2 mm
Surge voltage test
Result: Test passed
Temperature-rise test
Requirement temperature-rise test: Increase in temperature ≤45K
Result: Test passed
Power-frequency withstand voltage
Result: Test passed
Environmental and real-life conditionsNeedle-flame test
Time of exposure: 30 s
Result: Test passed
Packaging specificationsType of packaging: packed in cardboard
Technical Specs
ECLASSECLASS-11.0: 27141134
ECLASS-13.0: 27141134
ECLASS-12.0: 27141134
ETIMETIM 9.0: EC001283
UNSPSCUNSPSC 21.0: 39121400
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00426.pdf

Manufacturer_declaration_00113.pdf

Manufacturer_declaration_02530.pdf

Manufacturer_declaration_05482.pdf