PHOENIX CONTACT 0824500
PHOENIX CONTACT 0824500
PHOENIX CONTACTNot available

TMT 10 R CUS - Marker for terminal blocks

Marker for terminal blocks, can be ordered: by line, white, labeled according to customer specifications, mounting type: snap into universal marker groove, snap into flat marker groove, for terminal block width: 10.2 mm, lettering field size: 6.35x10.15mm
Product Code: 0824500
Partner cod.: 0824500
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Download
Tecnichal data
Product propertiesProduct type: Labeled terminal marker
Pitch: 10.2 mm
Type: flat
Marking
Number of individual labels per row: 10
MountingMounting type: snap into universal marker groove
Material specificationsColor: white
Material: Polyester
Base element material: Polyester foil
Components: free from silicone and halogen
Environmental and real-life conditionsTest for substances that would hinder coating with paint or varnish
Result: Test passed
Scratch test for the determining scratch resistance
Specification: DINÂENÂISOÂ1518-1:2019-10 (following)
Requirements: ≥Â5ÂN
Result: Test passed
Tesafilm test
Specification: DINÂENÂISOÂ2409:2013 (following)
Result: Test passed
UV resistance
Specification: ISOÂ4892-2:2013-03 (following)
Result: Test passed
Test duration: 96 h
Temperature resistance
Specification: ANSI/ULÂ969-2018:03 (following)
Test duration: 240 h
Rating 200°C (230°C): Test passed
Wipe resistance of inscriptions
Specification: DINÂENÂ61010-1 (VDEÂ0411-01):2020-03
DINÂENÂ62208 (VDEÂ0660-511):2012-06 (in parts)
ISOÂ175:2010 (following)
Test duration: 168 h
IRM 901: Test passed
IRM 902: Test passed
Testing in a condensation changing climate in the presence of sulfur dioxide
Specification: DINÂ50018:2013-05
Result: Test passed
Climate level: AHT 1.0 S
Cycles: 2
Salt spray test
Specification: DINÂENÂ60068-2-11:2000-02
Result: Test passed
Test duration: 96 h
Ambient conditions
Ambient temperature (operation): -40°C ... 120°C
Recommended storage conditions: 23°C / 50Â% relative humidity
Recommended ambient temperature (storage/transport): 23°C
Recommended humidity (storage/transport): 50 %
Shelf life: 2Âyears
DimensionsWidth: 10.15 mm
Length: 6.35 mm
Pitch: 10.2 mm
Standards and regulationsWipe resistance: DINÂENÂ61010-1 (VDEÂ0411-1)