Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1015533
PHOENIX CONTACTNot available

PSR-MC73-5NO-1DO-24DC-SC - Safety relays

Safety relay for emergency stop, safety doors, light grids up to SIL3, Cat.4, PLe, 1- or 2-channel operation, cross-circuit detection, can be retriggered, off-/on delay of 0.2s to 300s, 5enabling current paths, US=24VDC, plug-in screw terminal block
Product Code: 1015533
Partner cod.: 1015533
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Safety relays
Product family: PSRmini
Application: Emergency stop
Safety door
Light grid
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN61810-3
Times
Typical response time: < 50 ms (automatic start)
< 50 ms (manual, monitored start)
Typ. starting time with Us: 500 ms (with Us when controlled via A1)
Typical release time: < 25 ms (when controlled via S12andS22 (only for undelayed contacts))
< 10 ms (when controlled via A1; applicative deactivation via A1/A2 is not permitted)
Delay time range: 0.2 s ... 300 s ±5% (can be set for 47/48/58)
Restart time: < 1 s (Boot time)
Recovery time: 500 ms (following demand of the safety function)
Electrical propertiesMaximum power dissipation for nominal condition: 8.1 W (At US=30V, IL²=108 A²)
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VAC
Rated surge voltage/insulation: Basic insulation 4 kV between all current paths and housing
Safe isolation, reinforced insulation 6kV between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14) and enabling current path (23/24/34) and enabling current path (47/48/58)
Supply
Designation: A1/A2
Rated control circuit supply voltage US: 19.2 VDC ... 30 VDC
24 VDC -20%/+25%
Rated control supply current IS: typ. 80 mA
Power consumption at US: typ. 1.92 W
Inrush current: typ. 28 A (Δt=30µs at Us)
Filter time: 1 ms (For the logic. At A1 in the event of voltage dips at Us )
Protective circuit: Serial protection against polarity reversal; Suppressor diode
Input dataGeneral
Limit frequency: min. 0 Hz
max. 1 Hz
Digital: Sensor circuit (S12, S22)
Description of the input: safety-related sensor inputs
Number of inputs: 2
Input voltage range "0" signal: 0 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Input current range "0" signal: 0 mA ... 2 mA
Inrush current: < 11 mA (typically with US)
Filter time: max. 3 ms (Test pulse width of low test pulses)
min. 21 ms (Test pulse rate for low test pulse)
Concurrence: ∞
Limit frequency: min. 0 Hz
max. 1 Hz
Max. permissible overall conductor resistance: 150 Ω
Protective circuit: Varistor
Current consumption: < 4.5 mA (typically with US)
Digital: Start circuit (S34)
Description of the input: non-safety-related
Number of inputs: 1
Input voltage range "0" signal: 0 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Input current range "0" signal: 0 mA ... 2 mA
Inrush current: < 8.6 mA (typically with US)
Filter time: max. 1 ms (Test pulse width of low test pulses)
min. 21 ms (Test pulse rate for low test pulse)
Limit frequency: min. 0 Hz
max. 1 Hz
Max. permissible overall conductor resistance: 150 Ω
Protective circuit: Varistor
Current consumption: < 3.2 mA (typically with US)
Output dataRelay: Enabling current paths (13/14, 23/24/34, 47/48/58)
Output description: 2 N/O contacts each in series, safety-related, floating
Number of outputs: 3 (undelayed: 13/14, 23/24/34)
2 (delayed: 47/48/58)
Contact switching type: 5 enabling current paths
Contact material: AgCuNi +0.2µm...0.4µm Au / AgSnO2 +0.2µm Au
Switching voltage: min. 12 V AC/DC
max. 250 V AC/DC (Observe the load curve)
Switching capacity: min. 60 mW
Inrush current: min. 5 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-1: 4 A (24V (DC13))
3 A (230 V (AC 15))
Limiting continuous current: 6 A
Sq. Total current: 108 A2 (observe derating)
Switching frequency: 0.5 Hz (depending on the set delay time)
Mechanical service life: 10x 106 cycles
Output fuse: 6 A gL/gG
4 A gL/gG (for low-demand applications)
Signal: M1
Output description: PNP
non-safety-related
Number of outputs: 1
Voltage: approx. 23 VDC (US - 1 V)
Current: max. 100 mA
Maximum inrush current: 500 mA (Δt=10ms at Us)
Protective circuit: Suppressor diode
Short-circuit protection: Yes
Clock: S11, S21
Output description: PNP
non-safety-related
Number of outputs: 2
Voltage: corresponds toUS
Current: max. 100 mA
Maximum inrush current: 500 mA (Δt=10ms at Us)
Protective circuit: Suppressor diode
Short-circuit protection: Yes
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque: 0.5 Nm ... 0.6 Nm
SignalingStatus display: 5 x bi-color LED
DimensionsWidth: 22.5 mm
Height: 112.2 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 0
1
Safety data: ENISO13849
Category: 4
Performance level (PL): e (4ADC13; 3AAC15; 8760switching cycles/year)
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 3
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -35°C ... 60°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 85°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Shock: 10g (operation), 15g (transport)
Vibration (operation): 10Hz...150Hz, 2g
ApprovalsCE
Identification: CE-compliant
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: EN60664-1
MountingMounting type: DIN rail mounting
Assembly instructions: See derating curve
Mounting position: vertical or horizontal
Connection method: Screw connection
Technical Specs
ECLASSECLASS-11.0: 27371819
ECLASS-13.0: 27371819
ECLASS-12.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00529.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Certification_00206.pdf

Data_sheet_00124.pdf

Manufacturer_declaration_01111.pdf

Manufacturer_declaration_01583.pdf

Manufacturer_declaration_05474.pdf

Manufacturer_declaration_05868.pdf

Package_slip_01981.pdf

Technical_drawing_05621.pdf