Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1018702
PHOENIX CONTACT 1018702
PHOENIX CONTACTNot available

EV-CC-AC1-M3-CBC-RCM-ETH-3G - AC charging controller

AC charging controller in accordance with IEC61851-1, server for load distribution to up to 5 clients, OCPP 1.6J via 3G modem, Modbus/TCP via Ethernet, connection of RFID reader and energy meter via RS-485, DC residual current monitoring, connector release in the event of power failure
Product Code: 1018702
Partner cod.: 1018702
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: AC charging controller
Product family: CHARX control advanced plus
Application: AC charging controller for private and commercial applications (EU/CN)
Operating mode: Stand-Alone
Client
Server
Charging mode: Mode 3, Case B + C
System propertiesCharging controllers
Number of charging points: 1
Electrical propertiesType of charging current: AC
Current consumption: < 3 W (No-load)
Power consumption: < 10 W
Locking release in the event of mains failure: Integrated release function of the locking actuator for disconnection of Infrastructure Plug and Infrastructure Socket Outlet
Measuring current transducer
Connection method: Connector
Diameter of measuring coil: 15 mm
Measuring range: Residual current
Rated frequency fn: ≤ 2000 Hz
Nominal differential current: ± 300 mA
Residual current IΔn: 30 mA (AC)
6 mA (DC)
Rated current In: 32 A (Three-phase, 4x6mm²)
48 A (Single-phase)
Tripping time for IΔn: < 180 ms
Response time for 2 x IΔn: < 70 ms
Tripping time for 5xIΔn: < 20 ms
Supply
Supply voltage: 230 V
Supply voltage range: 100 VAC ... 240 VAC (nominal voltage range)
Nominal power consumption: < 3 W (No-load)
Power consumption: < 10 W (maximum)
Frequency range: 50 Hz ... 60 Hz
Input dataDigital
Number of digital inputs: 5
Description of the input: Digital input
Nominal current IN: ≤ 4 mA
Nominal input voltage UN: 12 V
Input voltage range: 0 V ... 3 V (Off)
Input voltage range U2: 9 V ... 15 V (On)
Output dataDigital
Output name: 4digital outputs
Connection technology: Screw connection
Maximum output voltage: 30 V
Maximum output current: 0.2 A (Total current for all outputs; internally supplied)
Maximum output current per channel: 0.6 A (Per output; externally supplied)
Switching
Output name: Relay output C1.2
Minimum switching capacity: 4000 VA
Maximum switching voltage: 250 VAC (External supply)
Max. switching current: 16 A
Switching​
Output name: Motor switching output
Maximum switching voltage: 12 V (Internal supply)
Max. switching current: 1 A (maximum)
Connection dataConductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 4 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
Conductor connection ​
Connection method: Screw connection
Conductor cross section rigid: 0.14 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1 mm²
Conductor cross section AWG: 26 ... 16
InterfacesInterface: Ethernet(1x)
Cellular communication(3G/2G)
Wireless
Interface description: HSPA/GSM/GPRS/EDGE cellular interface for communicating with higher-level management systems using the OCPP 1.6J communication protocol
Frequency: 900 MHz (HSPA)
2100 MHz (HSPA)
850 MHz (GSM/GPRS/EDGE)
900 MHz (GSM/GPRS/EDGE)
1800 MHz (GSM/GPRS/EDGE)
1900 MHz (GSM/GPRS/EDGE)
Transmission power: 2 W (GSM 850 (Class 4))
2 W (GSM 950 (Class 4))
1 W (GSM 1800 (Class 1))
1 W (GSM 1900 (Class 1))
+ 24 dBm (UMTS/HSPA (Class 3))
Number: 1
Connection method: SMA (male)
Impedance: 50 Ω
SIM Interface: Micro SIM (3FF)
Protocols supported: OCPP1.6J
RS-485
Interface: RS-485 2-wire
Bus system: RS-485
Connection method: Screw connection
Number of interfaces: 1 (for energy measurement device and RFID reader)
Number of supported devices: 2
Transmission speed range: 4.8 kbps ... 115.2 kbps (adjustable)
Protocols supported: Modbus/RTU (Master)
Ethernet
Interface: Ethernet
Connection method: RJ45 jack
Number of interfaces: 1
Serial transmission speed: 10/100 Mbps
Transmission length: 100 m
Protocols supported: Modbus/TCP
SignalingStatus display: 5x LEDs
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: < 2000 m
Permissible humidity (operation): 30 % ... 95 % (non-condensing)
ApprovalsConformity/Approvals
Conformance: CE-compliant
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
Noise immunity: EN 61000-6-2
Immunity to the discharge of static electricity: EN 61000-4-2: 8 kV air, 4 kV contact discharge
Immunity to electromagnetic fields: EN 61 000-4-3, 80---1000 MHz, 10 V/m
Immunity to conducted high frequency: EN 61 000-4-6, 0.15...80 MHz, 10 V
Immunity to fast transients (Burst): EN 61 000-4-4, 2 kV pos. and neg., 5 kHz
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Housing: DIN 43880
Noise emission: EN 61000-6-3
Standards and regulationsStandards
Standards/regulations: IEC 61851-1
MountingMounting type: DIN rail mounting
Assembly instructions: DIN rail mounting
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27144703
ECLASS-12.0: 27144703
ECLASS-13.0: 27144703
ETIMETIM 9.0: EC002889
UNSPSCUNSPSC 21.0: 39121800
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Manual_00018.pdf

Manufacturer_declaration_04378.pdf

Manufacturer_declaration_05874.pdf

Package_slip_01035.pdf

Software_update_00001.pdf

Technical_drawing_05736.pdf