PRT-PV-P-1500/20-680 - Type 2 surge arrester
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Notes | General Note: For use in all low-voltage systems between L-PEN. Only for use in IT systems between L-PE if the bodies of the equipment in the low-voltage system are connected to the grounding system of the transformer station. (common grounding of the HV transformer station and the bodies of the LV consumer's installation. RE = RA according to IEC 60364-4-442/VDE 0100-442 Figure 44D/example a) |
Product properties | IEC test classification: ï² EN type: PVï² Product type: PV arrester Product family: PRINTRAB Installation location: Interior Installation location of the disconnect device: Internal Accessibility: Accessible Connection configuration: Y configuration SPD failure behavior: OCFM Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Nominal frequency fN: 50 Hz (60Hz) Dielectric strength: < 5.8 kV DC (1min) < 4.2 kV AC (1min) Indicator/remote signaling Connection name: NC/NO Switching function: normal/deterioration Operating voltage: 30 VAC 30 VDC Operating current: 1 A AC 1 ADC |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/7c163b6322d195419144f8ceb34ee7d8/-S204x204-FJPG Width: 18.8 mm Height: 44 mm Depth: 41.9 mm (Without pin length) |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PBT 10 % GF / PA 6.6 Material group: I Housing material: PBT 10% GF/PA 6.6 |
Protective circuit | Nominal voltage UN: 400VAC (TN) 690VAC (TN) 500VAC (IT) Nominal frequency fN: 50 Hz (60Hz) Maximum continuous voltage UC: 680 VAC (Single) Residual current IPE: ⤠20 µA (2 in series/Ucpv) ⤠0.5 mA (Single/UREF) Nominal discharge current In (8/20) µs: 20 kA Maximum discharge current Imax (8/20) µs: 40 kA Short-circuit current rating ISCCR: 25 kA Voltage protection level Up: ⤠2.7 kV (Single) ⤠5.4 kV (2 serial connections) TOV behavior at UT (L-N): 953 VAC () 953 VAC (120min/failsafe mode) Response time tA: ⤠25 ns Max. backup fuse with branch wiring: 125 A (aR) PV protective circuit Connection configuration: Y configuration SPD failure behavior: OCFM Protective circuit DC voltage side (DC) Maximum discharge current Imax (8/20) µs: 40 kA Response time tA: ⤠25 ns Recommended backup fuse maximum: 100 A (gG) Insulation resistance Riso: > 5 Mé () Max. backup fuse with branch wiring: 125 A (aR) Nominal discharge current In (8/20) µs: 20 kA Continuous operating current ICPV: ⤠20 µA (2 serial connections) Maximum continuous operating voltage UCPV: 800 VDC (Single) 1600 VDC (2 serial connections) Residual current IPE: ⤠20 µA (2 in series/Ucpv) ⤠0.5 mA (Single/UREF) Voltage protection level Up: ⤠2.7 kV (Single) ⤠5.4 kV (2 serial connections) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP00 Ambient temperature (operation): -40°C ... 85°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠5000 m (Standard insulation) ⤠3000 m (Reinforced insulation) Permissible humidity (operation): 5 % ... 95 % Shock (operation): 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation): 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
Standards and regulations | Standards/specifications: IEC 61643-11 EN61643-11 IEC 61643-31 EN61643-31 |
Mounting | Mounting type: PCB mounting |