Industrial Automation
VAL-MS 1500DC-PV-ST - Type 2 surge protection plug
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Notes | General Note: The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area. |
Product properties | IEC test classification: PV II PV T2 EN type: T2 IEC power supply system: DC Type: Male Distance between live and grounded parts: 8 mm Product type: Replacement plug Product family: VALVETRAB MS Installation location: Interior Installation location of the disconnect device: Internal Accessibility: Accessible SPD failure behavior: OCFM (Open-Circuit Failure Mode) Surge protection fault message: optical Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Connection data | Connection method: pluggable |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3e02d9b64ee0a341a2e312513f1ad825/-S204x204-FJPG Width: 17.5 mm Height: 52.4 mm Depth: 55.3 mm Horizontal pitch: 1 Div. |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PA 6.6-FR PBT-FR Material group: I Housing material: PA 6.6-FR PBT-FR |
Protective circuit | Direction of action: (L+)-PE & (L-)-PE & (L+)-(L-) Standby power consumption PC: ⤠250 mVA Nominal discharge current In (8/20) µs: 15 kA Maximum discharge current Imax (8/20) µs: 30 kA Voltage protection level Up: ⤠2.5 kV Residual voltage Ures: ⤠1.9 kV (at 3kA) ⤠2.1 kV (at 5 kA) ⤠2.2 kV (at 10 kA) ⤠2.5 kV (at 15 kA) ⤠2.7 kV (at 20 kA) ⤠2.9 kV (at 30 kA) ⤠3 kV (at 40 kA) Response time tA: ⤠25 ns Protective circuit DC voltage side (DC) Open circuit voltage UOCSTC: ⤠625 VDC Maximum discharge current Imax (8/20) µs: 30 kA Response time tA: ⤠25 ns Nominal discharge current In (8/20) µs: 15 kA Continuous operating current ICPV: < 350 µA Maximum continuous operating voltage UCPV: 750 VDC Short-circuit current rating ISCPV: 2000 A Residual voltage Ures: ⤠1.9 kV (at 3kA) ⤠2.1 kV (at 5 kA) ⤠2.2 kV (at 10 kA) ⤠2.5 kV (at 15 kA) ⤠2.7 kV (at 20 kA) ⤠2.9 kV (at 30 kA) ⤠3 kV (at 40 kA) Voltage protection level Up: ⤠2.5 kV Standby power consumption PC: ⤠250 mVA Additional technical data Maximum discharge current Imax (8/20) µs: 40 kA Nominal discharge current In (8/20) µs: 20 kA (4x (5x In|120 s)|30 min)) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 85°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠3000 m (amsl) Permissible humidity (operation): 5 % ... 95 % Shock (operation): 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation): 5g (5-500 Hz/2.5 h/XYZ) |
Approvals | UL specifications Maximum continuous operating voltage MCOV: 1500 VDC Short-circuit current rating (SCCR): 50 kA Voltage protection rating VPR: 4 kV Nominal discharge current In: 10 kA Mode of protection: (DC+) - (DC-) (DC+) - G (DC-) - G Nominal voltage: 1500 VDC Power distribution system: DCPV SPD Type: 1CA |
Standards and regulations | Standards/specifications: EN61643-31 IEC 61643-31 Note: 2019 2018 |
Mounting | Mounting type: on base element |
ECLASS | ECLASS-11.0: 27130890 ECLASS-13.0: 27171492 |
ETIM | ETIM 9.0: EC002496 |
UNSPSC | UNSPSC 21.0: 39121620 |
Description other products