Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 1044386
PHOENIX CONTACTNot available

FLT-SEC-T1+T2-3IT-350/25-FM - Type1+2 special combined lightning current and surge arrester

Plug-in lightning and surge protective device combination, in accordance with Type 1+2 / Class I+II, for 3-phase power supply networks in isolated operation with separate N and PE (L1, L2, L3, N, PE).
Product Code: 1044386
Partner cod.: 1044386
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesGeneral
Note: Usable in all low-voltage systems between L-N or L-PEN.
Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected to the earthing arrangement of the transformer substation. (interconnected earthing arrangement of the HV-transformer substation with the bodies of the LV-installation. RE = RA accordance to IEC 60364-4-442 / VDE 0100-442 Fig. 44D / Example a)
Product propertiesIEC test classification: I + II
T1 + T2
EN type: T1 + T2
IEC power supply system: IT
Type: DIN rail module, two-section, divisible
Product type: Arrester combination
Product family: SEC Family
Number of positions: 4
Surge protection fault message: Optical, remote indicator contact
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal frequency fN: 50 Hz (60Hz)
Indicator/remote signaling
Connection name: Remote fault indicator contact
Switching function: Changeover contact
Operating voltage: 12 VAC ... 250 VAC
125 VDC (200 mA DC)
Operating current: 10 mA AC ... 1 A AC
1 ADC (30VDC)
Connection dataConnection method: Screw terminal blocks
Fork-type cable lug
Screw thread: M5
Tightening torque: 4.5 Nm
Stripping length: 18 mm
Conductor cross section flexible: 2.5 mm² ... 35 mm²
1.5 mm² ... 16 mm²
Conductor cross section rigid: 2.5 mm² ... 35 mm²
Conductor cross section AWG: 13 ... 2
Remote fault indicator contact
Connection method: Plug-in/screw connection via COMBICON
Screw thread: M2
Tightening torque: 0.25 Nm
Stripping length: 7 mm
Conductor cross section flexible: 0.14 mm² ... 1.5 mm²
Conductor cross section rigid: 0.14 mm² ... 1.5 mm²
Conductor cross section AWG: 28 ... 16
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/451fb5127778984cb1086262d9da7b7e/-S204x204-FJPG
Width: 142.4 mm
Height: 95.2 mm
Depth: 74.5 mm
Horizontal pitch: 8 Div.
Material specificationsFlammability rating according to UL 94: V-0
CTI value of material: 600
Insulating material: PA6.6-FR 20% GF
PBT-FR
Material group: I
Housing material: PA 6.6-FR 20% GF
PBT-FR
Mechanical propertiesMechanical data
Open side panel: No
Protective circuitMode of protection: L-N
L-PE
N-PE
Direction of action: 3L-N & N-PE
Nominal voltage UN: 240/415VAC (IT)
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous voltage UC: 350 VAC
Rated load current IL: 125 A (< 55°C)
Residual current IPE: ≤ 0.5 mA
Nominal discharge current In (8/20) µs: 25 kA
Impulse discharge current (10/350)µs, charge: 12.5 As
Impulse discharge current (10/350)µs, specific energy: 160 kJ/Ω
Impulse discharge current (10/350)µs, peak value limp: 25 kA
Follow current interrupt rating Ifi: 25 kA (264 V AC)
3 kA (350 V AC)
Short-circuit current rating ISCCR: 25 kA (264 VAC)
3 kA (350 V AC)
Voltage protection level Up (L-N): ≤ 1.5 kV
Voltage protection level Up (L-PE): ≤ 2.8 kV
Voltage protection level Up (N-PE): ≤ 1.5 kV
Residual voltage Ures (L-N): ≤ 1.5 kV (at In)
≤ 1.2 kV (at 10 kA)
≤ 1 kV (at 5 kA)
≤ 0.9 kV (at 3kA)
Residual voltage Ures (L-PE): ≤ 2.8 kV (at In)
≤ 2.4 kV (at 10 kA)
≤ 2 kV (at 5 kA)
≤ 1.8 kV (at 3kA)
Residual voltage Ures (N-PE): ≤ 1.5 kV (at In)
≤ 1.2 kV (at 10 kA)
≤ 1 kV (at 5 kA)
≤ 0.9 kV (at 3kA)
TOV behavior at UT (L-N): 415 VAC (5s / withstand mode)
440 VAC (120min / safe failure mode)
Response time tA: ≤ 25 ns
Max. backup fuse with V-type through wiring: 125 A (gG)
Max. backup fuse with branch wiring: 315 A (gG)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (only when all terminal points are used)
Ambient temperature (operation): -40°C ... 80°C
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 2000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Shock (operation): 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation): 5g (5 - 500 Hz/2.5 h/X, Y, Z)
Standards and regulationsStandards/specifications: IEC 61643-11
Note: 2011
EN 61643-11
Standards/specifications: EN61643-11
Note: 2012
MountingMounting type: DIN rail: 35 mm
Technical Specs
ECLASSECLASS-11.0: 27130808
ECLASS-13.0: 27171204
ETIMETIM 9.0: EC001457
UNSPSCUNSPSC 21.0: 39121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01865.pdf

Flyer_00003.pdf

Flyer_00002.pdf

Flyer_00001.pdf

Manufacturer_declaration_00787.pdf

Manufacturer_declaration_02077.pdf

Technical_drawing_06386.pdf