Industrial Automation
AXC F 3152 - Controller


Product properties | Type: modular Product type: Controller Product family: PLCnext Control Insulation characteristics Protection class: III (IEC 61140, ENÃ61140, VDEÃ0140-1) Overvoltage category: II Pollution degree: 2 Display Diagnostics display: No |
System properties | Processor: Intelî Atomâ⢠x5-E3930 2x 1.3 GHz Flash memory: 1 GByte (internal flash memory) SD card from PhoenixÃContact (for external flash memory, see accessories) Retentive data storage: 1 Mbyte RAM: 2048 Mbyte IoT capability: PROFICLOUD IoT platform: PROFICLOUD Supports cloud computing: yes IEC 61131 runtime system Program memory: 12 Mbyte Data storage system: 32 Mbyte Axioline Amount of process data: max. 1482 Byte (per station (total input and output data)) max. 1024 Byte (AxiolineÃF local bus (input)) max. 1024 Byte (AxiolineÃF local bus (output)) Number of supported devices: max. 63 (per station) Number of local bus devices that can be connected: max. 63 (observe current consumption) PROFINET Device function: PROFINET controller, PROFINET device Update rate: min. 1 ms (32Ãparticipants) min. 2 ms (64 devices) min. 4 ms (128Ãparticipants) Conformance Class: B Supported functions: FSU PROFINET controller Device ID: 0158hex Vendor ID: 00B0hex Function Diagnostics display: No Controller redundancy: yes Safety function: No Functionality Programming languages supported: Symbolic flowchart (SFC) Ladder diagram (LD) Function block diagram (FBD) Structured text (ST) C++ C# Java Python Simulink System requirements Engineering tool: PLCnext Engineer Eclipse Visual Studio MATLABî Simulinkî Application interface: OPCÃUA |
Electrical properties | Real-time clock Realtime clock: Yes Description realtime clock: 0.7Ãs/day = 8Ãppm at 25ðC Potentials: Communications power U Supply voltage: 24 VÃDC Supply voltage range: 19.2 VÃDC ... 30 VÃDC (including all tolerances, including ripple (ñÃ5Ã%)) Current draw: max. 504 mA (with 1ÃA at UBus for the I/Os and UL = 24 V) Power consumption: max. 12.1 W (with 1ÃA at UBus for the I/Os and UL = 24 V) Protective circuit: Surge protection; electronic Reverse polarity protection; electronic Potentials: AxiolineÃF local bus supply (U Supply voltage: 5 VÃDC (via bus base module) Power supply unit: 1 A |
Connection data | AxiolineÃF connector Connection method: Push-in connection Conductor cross section, rigid: 0.2 mm² ... 1.5 mm² Conductor cross section, flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm |
Interfaces | Supported protocols: HTTP HTTPS PROFINET INTERBUS Modbus/TCP (via corresponding library) Modbus/RTU (via corresponding library) Ethernet/IP (Adapter) CANopenî (via corresponding library) DALI (via corresponding library) DALI2 (via corresponding app) HART (via corresponding app) IO-Link (via corresponding app) PROFIBUS MQTT (via corresponding app) OPCÃUAÃServer OPCÃUAÃClient (via corresponding app) DHCP (via corresponding app) SFTP SMTP (via corresponding app) SNTP (via corresponding app) SNMP (via corresponding app) DNS (via corresponding app) DNP3 (via corresponding app) IEC 60870-5-1 (via corresponding library) IEC 60870-5-104 (via corresponding library) IPsec syslog Web server: yes AxiolineÃF local bus Number of interfaces: 1 Connection method: Bus base module Transmission speed: 100 Mbps Ethernet Bus system: RJ45 Number of interfaces: 3 Connection method: RJ45 jack Note on the connection method: Auto negotiation and autocrossing Transmission speed: 10/100/1000 Mbps Transmission physics: Ethernet in RJ45 twisted pair Transmission length: max. 100 m Service Bus system: USB Number of interfaces: 1 Connection method: USB type C Note on the connection method: Only device interface |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/70b435cc67cf824998898528b4c68cdc/-S204x204-FJPG Width: 100 mm Height: 126.93 mm Depth: 75 mm Note on dimensions: The depth applies when a THÃ35-7.5 DIN rail is used (in accordance with ENÃ60715). |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 60°C up to 2000Ãm above mean sea level (observe derating) -25°C ... 55°C up to 3000Ãm above mean sea level (observe derating) 55°C (with max. 1ÃA on UBus) 55°C ... 60°C (only in conjunction with an Axioline F power module AXL F PWR 1H (Item no. 2688297)) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 5 % ... 95 % (according to DINÃENÃ61131-2) Permissible humidity (storage/transport): 5 % ... 95 % (according to DINÃENÃ61131-2) Shock (operation): 30g (in accordance with ENÃ60068-2-27/IEC 60068-2-27) Vibration (operation): 5g (in accordance with ENÃ60068-2-6/IEC 60068-2-6) Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Ãm above sea level) Air pressure (storage/transport): 58 kPa ... 106 kPa (up to 4500Ãm above mean sea level) |
Approvals | UL, USA/Canada Identification: cULus Certificate: E238705 Corrosive gas test Identification: ISAÃS71.04.2013 G3 Harsh Group A, DINÃENÃ60068-2-60:2016-06 MethodÃ4 Industrial Cyber Security Identification: IndustrialÃITÃSecurity, IACSÃComponent Certificate: IITS2Ã029429Ã0027 Note: Configuration: SecurityÃProfileÃactive |
EMC data | Conformance with EMC directives: Immunity test in accordance with ENÃ61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)ENÃ61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge Immunity test in accordance with ENÃ61000-6-2/IEC 61000-6-2 Electromagnetic fieldsENÃ61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m Immunity test in accordance with ENÃ61000-6-2/IEC 61000-6-2 Fast transients (burst)ENÃ61000-4-4/IEC 61000-4-4 Criterion B, 2ÃkV Immunity test in accordance with ENÃ61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)ENÃ61000-4-5/IEC 61000-4-5 CriterionÃB; DC supply lines: ñ0.5ÃkV/ñ1.0ÃkV (symmetrical/asymmetrical), fieldbus cable shielding: ñ1.0ÃkV Immunity test in accordance with ENÃ61000-6-2/IEC 61000-6-2 Conducted interferenceENÃ61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V Noise emission test in accordance with ENÃ61000-6-3/IEC 61000-6-3 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU |
Mounting | Mounting type: DIN rail mounting Connection method: Push-in connection |
Description other products